5S Study: Safe and Simple Single Shot Pulmonary Vein Isolation With Pulsed Field Ablation Using Sedation

Author:

Schmidt Boris12ORCID,Bordignon Stefano1ORCID,Tohoku Shota1,Chen Shaojie1,Bologna Fabrizio1ORCID,Urbanek Lukas1,Pansera Francesco1ORCID,Ernst Matthias1,Chun K.R. Julian1ORCID

Affiliation:

1. Cardioangiologisches Centrum Bethanien (B.S., S.B., S.T., S.C., F.B., L.U., F.P., M.E., K.R.J.C.), Frankfurt, Germany.

2. Universitätsklinikum Frankfurt, Medizinische Klinik 3- Klinik für Kardiologie (B.S.), Frankfurt, Germany.

Abstract

Background: Pulsed field ablation represents an energy source specific for ablation of cardiac arrhythmias including atrial fibrillation. The aim of the study was to describe the adoption and the process of streamlining procedures with a new ablation technology. Methods: All-comer atrial fibrillation patients (n=191; mean age 69±12 years) underwent catheter ablation with a pulsed field ablation ablation device exclusively using analog-sedation. In the validation phase (n=25), device electrogram quality was compared with a circular mapping catheter to assess pulmonary vein isolation and esophageal temperature monitoring was used. In the streamline phase (n=166), a single-catheter approach was implemented. Postprocedural cerebral magnetic resonance imaging was performed in 53 patients. In 52 patients, esophageal endoscopy was performed at day 1 after the procedure. Follow-up was performed using 72 hours Holter ECGs. Results: On a pulmonary vein basis, pulmonary vein isolation rate was 100% including a single shot isolation rate of 99.5%. The electrogram information of the pulsed field ablation catheter and the circular mapping catheter were 100% congruent. Neither esophageal temperature rises nor esophageal thermal injury were observed. Two minor strokes occurred, presumable due to air embolism during catheter exchanges through the large bore sheath (13.8 F ID). In the streamline phase, reduced procedure times (46±14 versus 38±13 minutes, P =0.004), no further strokes and a low incidence of silent cerebral injury (10/53 patients; 19%) were noted. During short-term follow-up, 17/191 patients (9%) had a atrial tachyarrhythmia recurrence. Conclusions: The pulsed field ablation device allows for simple and safe simple single shot pulmonary vein isolation using standard sedation protocols. Procedural speed and efficacy are remarkable and streamlining measures have added safety.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3