1. From the Department of Internal Medicine, Division of Cardiology, Saint Louis University Health Sciences Center, Mo, and Service D’Explorations Fonctionnelles (P.D., E.A., J.-L.D.-R.), Unite D’Hemodynamique et de Cardiologie Interventionnelle, Henri Mondor University Hospital, University of Paris XII, Creteil, France.

Abstract

Background —Absolute coronary flow velocity reserve (CVR) after stenting may remain abnormal as a result of several different mechanisms. Relative CVR (rCVR=CVR target /CVR reference ) theoretically normalizes for global microcirculatory disturbances and facilitates interpretation of abnormal CVR. Methods and Results —To characterize potential mechanisms of poststent physiology, CVR was measured using a Doppler-tipped angioplasty guidewire in 55 patients before and after angioplasty, after stenting, and in an angiographically normal reference vessel. For the group, the percent diameter stenosis decreased from 75±13% to 40±18% after angioplasty and to 10±9% (all P <0.05) after stent placement. After angioplasty, CVR increased from 1.63±0.71 to 1.89±0.55 ( P <0.05) and after stent placement, to 2.48±0.75 ( P <0.05 versus pre- and postangioplasty). After angioplasty, rCVR increased from 0.64±0.26 to 0.75±0.23 and after stent placement to 1.00±0.34. In 17 patients with CVR stent ≤2.0, increased basal coronary flow, rather than attenuated hyperemia, was responsible in large part for the lower CVR stent compared with patients having CVR stent >2.0. In 8 patients with CVR stent <2.0, a normal rCVR supported global microvascular disease. The subgroup of 9 patients with CVR stent <2.0 and abnormal rCVR (16% of the studied patients) may require a pressure-derived fractional flow reserve to differentiate persistent obstruction from diffuse atherosclerotic disease or microvascular stunning. Conclusions —Although a majority of patients after stenting normalize CVR for the individual circulation (ie, normal CVR or normal rCVR), in those with impaired CVR stent , the analysis of coronary flow dynamics suggests several different physiological mechanisms. Additional assessment may be required to fully characterize the physiological result for such patients to exclude remediable luminal abnormalities.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3