Accuracy of In Vivo Carotid B-Mode Ultrasound Compared With Pathological Analysis

Author:

Schulte-Altedorneburg Gernot1,Droste Dirk W.1,Felszeghy Szabolcs1,Kellermann Mónika1,Popa Vasile1,Hegedüs Katalin1,Hegedüs Csaba1,Schmid Martina1,Módis László1,Ringelstein E. Bernd1,Csiba László1

Affiliation:

1. From the Department of Neurology (G.S.-A., V.P., K.H., L.C.), the Department of Anatomy, Histology, and Embryology (S.F., L.M.), the Department of Psychiatry (M.K.), and the Department of Stomatology (C.H.), University of Debrecen, Medical and Health Science Centre, Faculty of Medicine, Debrecen, Hungary; the Department of Neurology (G.S.-A., D.W.D., E.B.R.), University of Münster, Münster, Germany; and the Institute for Medical Informatics, Biometry and Epidemiology (M.S.), University of Munich,...

Abstract

Background and Purpose —This study aimed to determine the correlation of in vivo ultrasound measurements of intima-media thickening (IMT), lumen diameter, and cross-sectional area of the common carotid artery (CCA) with corresponding measurements obtained by gross pathology and histology. Methods —Sixty-six moribund neurological patients (mean age 71 years) underwent B-mode ultrasound of the CCA a few days before death. During autopsy, carotid specimens were removed in toto. Carotid arteries were ligated and cannulated for injection of a hydrophilic embedding material under standardized conditions. The carotid bifurcation was frozen and cut manually in 3-mm cross slices. Digital image analysis was carried out to determine the diameter and the cross-sectional area of the frozen slices of the CCA. IMT was assessed by light microscope. Ultrasonic and planimetric data were compared. Results —Mean measurements of lumen diameter and cross-sectional area were 7.13±1.27 mm and 0.496±0.167 cm 2 , respectively, by ultrasound, and 7.81±1.45 mm and 0.516±0.194 cm 2 , respectively, by planimetric analysis of the unfixed redistended carotid arteries ( R 2 =0.389 and 0.497). The mean IMT was 1.005±0.267 mm by ultrasound and 0.67±0.141 mm histologically, resulting in a mean difference of −31%. Conclusions —Transcutaneous B-mode ultrasound provides a reliable approach for in vivo measurements of the cross-sectional area and, less exactly, of the lumen diameter of the CCA. Compared with histological results, in vivo ultrasound measurements of the IMT are systematically larger.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Cited by 46 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3