Duplex Ultrasound and Magnetic Resonance Angiography Compared With Digital Subtraction Angiography in Carotid Artery Stenosis

Author:

Nederkoorn Paul J.1,van der Graaf Yolanda1,Hunink M.G. Myriam1

Affiliation:

1. From the Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht, the Netherlands (P.J.N., Y.v.d.G.), and Program for the Assessment of Radiologic Technology, Department of Epidemiology and Biostatistics and Department of Radiology, Erasmus Medical Center, Rotterdam, the Netherlands, and Department of Health Policy and Management, Harvard School of Public Health, Boston, Mass (M.G.M.H.).

Abstract

Background and Purpose— The purpose of this work was to review and compare published data on the diagnostic value of duplex ultrasonography (DUS), MR angiography (MRA), and conventional digital subtraction angiography (DSA) for the diagnosis of carotid artery stenosis. Methods— We performed a systematic review of published studies retrieved through PUBMED, from bibliographies of review papers, and from experts. The English-language medical literature was searched for studies that met the selection criteria: (1) The study was published between 1994 and 2001; (2) MRA and/or DUS was performed to estimate the severity of carotid artery stenosis; (3) DSA was used as the standard of reference; and (4) the absolute numbers of true positives, false negatives, true negatives, and false positives were available or derivable for at least one definition of disease (degree of stenosis). Results— Sixty-three publications on duplex, MRA, or both were included in the analysis, yielding the test results of 64 different patient series on DUS and 21 on MRA. For the diagnosis of 70% to 99% versus <70% stenosis, MRA had a pooled sensitivity of 95% (95% CI, 92 to 97) and a pooled specificity of 90% (95% CI, 86 to 93). These numbers were 86% (95% CI, 84 to 89) and 87% (95% CI, 84 to 90) for DUS, respectively. For recognizing occlusion, MRA yielded a sensitivity of 98% (95% CI, 94 to 100) and a specificity of 100% (95% CI, 99 to 100), and DUS had a sensitivity of 96% (95% CI, 94 to 98) and a specificity of 100% (95% CI, 99 to 100). A multivariable summary receiver-operating characteristic curve (ROC) analysis for diagnosing 70% to 99% stenosis demonstrated that the type of MR scanner predicted the performance of MRA, whereas the presence of verification bias predicted the performance of DUS. For diagnosing occlusion, no significant heterogeneity was found for MRA; for DUS, the presence of verification bias and type of DUS scanner were explanatory variables. MRA had a significantly better discriminatory power than DUS in diagnosing 70% to 99% stenosis (regression coefficient, 1.6; 95% CI, 0.37 to 2.77). No significant difference was found in detecting occlusion (regression coefficient, 0.73; 95% CI, −2.06 to 3.51). Conclusions— These results suggest that MRA has a better discriminatory power compared with DUS in diagnosing 70% to 99% stenosis and is a sensitive and specific test compared with DSA in the evaluation of carotid artery stenosis. For detecting occlusion, both DUS and MRA are very accurate.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 312 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3