Comparative accuracy of two-dimensional echocardiography and Doppler pressure half-time methods in assessing severity of mitral stenosis in patients with and without prior commissurotomy.

Author:

Smith M D,Handshoe R,Handshoe S,Kwan O L,DeMaria A N

Abstract

This study was undertaken to compare the accuracies of the two-dimensional echocardiographic (2DE) and Doppler pressure half-time methods for the noninvasive estimation of cardiac catheterization measurements of mitral valve area in patients with pure mitral stenosis both with and without a previous commissurotomy. Data were retrospectively obtained from 74 consecutive patients who underwent cardiac catheterization within a 30 month period for evaluation of mitral stenosis, and who had two-dimensional echocardiograms performed before catheterization. Six patients (8.1%) had technically inadequate 2DE images and their data were excluded from analysis. Two of these patients had undergone commissurotomy, while the remaining four had not. Continuous-wave Doppler echocardiographic examinations were attempted in 45 patients and adequate measurements of pressure half-times were obtained in all patients studied. Mitral valve area by two-dimensional echocardiography was measured as the planimetered area along the inner border of the smallest mitral orifice visualized during short-axis scanning, while pressure half-time was calculated as the interval between the peak transmitral velocity and velocity/square root 2 as measured from the envelope of the Doppler spectral signal. Calculations from catheterization represented the minimal valve area at rest as derived from the Gorlin formula with the use of pressure gradients and thermodilution measurements of cardiac output. Thirty-seven of the patients had had a previous mitral commissurotomy a mean of 11.2 +/- 5.4 years before, while the remaining 37 patients were previously unoperated. Mean valve area as determined at catheterization for the total group of patients ranged from 0.37 to 2.30 cm2 (mean = 1.08 +/- 0.42 cm2).(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 152 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3