Determination of the Upper Limit of Vulnerability Using Implantable Cardioverter-Defibrillator Electrograms

Author:

Swerdlow Charles1,Shivkumar Kalyanam1,Zhang Jianxin1

Affiliation:

1. From Cedars-Sinai Medical Center (C.S., J.Z.) and David Geffen School of Medicine at UCLA (K.S.), Los Angeles, Calif.

Abstract

Background— The upper limit of vulnerability (ULV) correlates with the defibrillation threshold and can be determined with 1 episode of ventricular fibrillation (VF). To automate the ULV in an implantable cardioverter-defibrillator (ICD), the most vulnerable intervals must be identified from an ICD electrogram rather than the latest-peaking surface T wave (T peak ). We hypothesized that the recovery time (T R ), defined as the maximum derivative (dV/dt) of the T wave of the shock electrogram, correlates with the most vulnerable intervals. Methods and Results— We determined ULV, defibrillation threshold, and the most vulnerable intervals in 25 patients at ICD implantation. The ULV was the weakest T-wave shock that did not induce VF. The most vulnerable intervals were the ones associated with the strongest shocks that induced VF. Telemetered shock electrograms were stored on digital tape and differentiated offline to measure T R . T peak and T R were highly correlated (T peak −T R =−2±11 ms; ρ=0.80, P <0.001). At least 1 most vulnerable interval timed between −20 ms and +20 ms relative to T peak in all patients and between −40 ms and +20 ms relative to T R in 96% of patients. Conclusions— The recovery time of shock electrograms provides accurate information about global repolarization. T R closely approximates T peak . The ULV method may be automated in an ICD by timing T-wave shocks relative to T R .

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Ventricular Fibrillation and Defibrillation;Reference Module in Biomedical Sciences;2024

2. OBSOLETE: Ventricular Fibrillation and Defibrillation;Reference Module in Biomedical Sciences;2018

3. Ventricular Fibrillation and Defibrillation;Encyclopedia of Cardiovascular Research and Medicine;2018

4. Reducing ICD Test Shocks with a Simplified Upper Limit of Vulnerability;Pacing and Clinical Electrophysiology;2016-04-22

5. Assessment of Adequate Safety Margin Using Single Coupling Interval-Upper Limit of Vulnerability Test;Pacing and Clinical Electrophysiology;2013-08-26

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3