Localization of center of gravity of helmet systems in the human anatomical frame using 3D laser scanners

Author:

Nayak Sabyasachi1,Sekhar Binu M2,Tripathy Neeraj Kumar3,Joshi Vijay Vishnu4

Affiliation:

1. Department of Human Engineering, Institute of Aerospace Medicine, Bengaluru, Karnataka, India,

2. Head of the Department, Department of Human Engineering, Institute of Aerospace Medicine, Bengaluru, Karnataka, India,

3. Senior Advisor in Aerospace Medicine and Chief Research Officer, Institute of Aerospace Medicine, Indian Air Force, Bengaluru, Karnataka, India,

4. Specialist in Aerospace Medicine, Institute of Aerospace Medicine, Bengaluru, Karnataka, India,

Abstract

Introduction: An accurate assessment of the Center of Gravity (CoG) and mass properties of aircrew helmets and helmet-mounted devices is an essential requirement to predict neck injury potential. Conventionally, trifilar pendulum method is used for the assessment of CoG shift and calculation of force moment and mass moment. In this study, a new procedure is described to obtain a more precise measurement of the CoG of the helmet as well as the combined head and helmet system. Material and Methods: Measurement of the helmet mass and CoG properties was done using a trifilar pendulum and the geometrical properties of the helmet and head were obtained using a 3D laser scanner. The required coordinate transformations from the laboratory frame to the anatomical frame using the 3D scanner as a coordinate digitizer. The head sizes used in the calculations ranged from small female head to large male head and a single average head CoG position was used to calculate the combined head and helmet CoG. Results: The error of the 3D scanner method for combined head and helmet CoG measurement as compared to the trifilar pendulum method varied between 0.3 mm and 0.4 mm with an average error of 0.4 mm. This method could also successfully calculate the combined CoG of the helmet on various head sizes ranging from small female to large male heads. Conclusion: The 3D laser scanner-based CoG measurement gave similar results as compared to the present method of CoG measurement when the medium-sized anthropomorphic test dummy head was considered. The localization of helmet CoG in the anatomical frame would allow more accurate measurements of force moment and mass moment. The same methodology could also be used to calculate the combined head and helmet CoG of different head and helmet masses.

Publisher

Scientific Scholar

Subject

General Medicine

Reference15 articles.

1. Determination of helmet CG and evaluation of neck injury potentials using “Knox Box criteria” and neck torque limits;Gaur;IJASM,2013

2. Biodynamic Testing of Helmet-mounted Systems;Perry,1993

3. Neck Muscle Fatigue Resulting From Prolonged Wear of Weighted Helmets, Air Force Research Laboratory, Wright-Patterson AFB, OH, Report No. AFRL-RH-WP-TR-2008-0096;Gallagher,2008

4. Inertial properties of football helmets;Funk;J Biomech Eng,2018

5. Mass properties comparison of dismounted and ground-mounted head-supported mass configurations to existing performance and acute injury risk guidelines;Estep;Mil Med,2019