Improvement of Hepatitis C Virus (HCV) Genotype Determination with the New Version of the INNO-LiPA HCV Assay

Author:

Bouchardeau Françoise1,Cantaloube Jean François2,Chevaliez Stéphane3,Portal Christine1,Razer Annie1,Lefrère Jean-Jacques4,Pawlotsky Jean Michel3,De Micco Philippe2,Laperche Syria1

Affiliation:

1. Centre National de Référence pour les Hépatites B et C en Transfusion, Laboratoire d'Expertise en Virologie, Institut National de la Transfusion Sanguine, Paris, France

2. Unité des Virus Émergents EA3292, Etablissement Français du Sang Alpes-Méditerranée, Marseille, France

3. Centre National de Référence des Hépatites B, C, et Delta, Laboratoire de Virologie and INSERM U635, Hôpital Henri Mondor, Université Paris 12, Créteil, France

4. Département des Agents Transmissibles par le Sang, Institut National de la Transfusion Sanguine, Paris, France

Abstract

ABSTRACT Hepatitis C virus (HCV) isolates have been classified into six main genotypes. Genotyping methods, and especially the widely used line probe assay (LiPA), are frequently based on the 5′-untranslated region (5′UTR). However, this region is not appropriate for discriminating HCV strains at the subtype level and for distinguishing many genotype 6 samples from genotype 1. We investigated the capacity of a novel LiPA (Versant HCV Genotype 2.0 assay) based on the simultaneous detection of 5′UTR and Core regions for genotypes 1 and 6 to provide correct HCV genotypes (characterized with a phylogenetic analysis) in a set of HCV strains mainly encountered in Western countries. The improvement was assessed by comparing the results to those obtained with the previous version of the assay. Of the 135 tested samples, 64.7% were concordant for genotype group and subtype with sequencing reference results using the Versant HCV Genotype 2.0 assay versus 37.5% with the previous version. The yield was mainly related to a better characterization of genotype 1, since the accuracy, tested in 62 genotype 1 samples, increased from 45.2% with the first version to 96.8% with the new one. However, this new version necessitates a specific PCR and could no longer be used after 5′UTR PCR used for current HCV infection diagnosis. Moreover, the information provided by 5′UTR hybridization is not reliable for correctly identifying the diversity within genotypes 2 and 4. Thus, the Versant HCV Genotype 2.0 assay remains a useful tool for clinical practice when only the discrimination between major HCV genotypes is necessary.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3