Microbiological Evaluation of Protected Environments During Patient Occupancy

Author:

Bodey Gerald P.12,Johnston Dianne12

Affiliation:

1. Department of Developmental Therapeutics, The University of Texas M. D. Anderson Hospital, Houston, Texas 77025

2. Tumor Institute at Houston, Houston, Texas 77025

Abstract

Microbiological monitoring has been conducted in two life island (LI) units and two laminar airflow (LAF) rooms while they were occupied by patients undergoing cancer chemotherapy. There were only 5 organisms per 1,000 ft 3 of air sampled in LAF rooms, 31 organisms in LI units, and over 3,000 organisms in regular hospital rooms. None of the floor samples obtained from hospital rooms was sterile, compared to over 70% in LAF rooms. The rate of deposition of organisms onto settling plates was one organism per 4.5 hr in LAF rooms compared to one organism per 0.08 hr in hospital rooms. Potential pathogens were isolated much more frequently from environmental samples obtained from hospital rooms than from LI units or LAF rooms. Two sites of persistent contamination arose in the LAF rooms: the vinyl tile flooring and the water supply system. Over half of the potential pathogens cultured from the protected environment units were cultured initially from the patients who occupied the units.

Publisher

American Society for Microbiology

Subject

General Pharmacology, Toxicology and Pharmaceutics,General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com