Comparison of the Xpert MTB/RIF and Cobas TaqMan MTB Assays for Detection of Mycobacterium tuberculosis in Respiratory Specimens

Author:

Park Kyung Sun1,Kim Ji-Youn2,Lee Jung Wha2,Hwang Yu-Yean1,Jeon Kyeongman3,Koh Won-Jung3,Ki Chang-Seok1,Lee Nam Yong1

Affiliation:

1. Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea

2. Center for Clinical Medicine, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Republic of Korea

3. Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea

Abstract

ABSTRACT The Xpert MTB/RIF assay (Cepheid, Sunnyvale, CA) is a fully automated, cartridge-based real-time PCR assay designed to detect Mycobacterium tuberculosis and rifampin resistance within 2 h. The performance of the Xpert assay has been evaluated in various clinical settings. However, there are few data comparing the Xpert assay to the Cobas TaqMan MTB test (Roche Diagnostics, Basel, Switzerland), one of the most widely utilized molecular assays for M. tuberculosis detection. In this prospective study, 320 consecutive respiratory specimens were processed simultaneously using acid-fast bacillus (AFB) staining, mycobacterial cultures with both solid and liquid media, and the Cobas and Xpert assays. The Xpert assay was performed with direct respiratory specimens, while the Cobas assay was done with decontaminated concentrated specimens. Based on the culture as a reference method, the overall sensitivities of the Cobas and Xpert assays were 71.4% and 67.9%, respectively. When AFB smear results were taken into consideration, the sensitivities of the Cobas assay for smear-positive and -negative specimens were 87% and 54%, while those of the Xpert assay were 67% and 69%, respectively. The Cobas assay showed 100% specificity and 100% positive predictive value (PPV) regardless of smear results, while the Xpert assay showed 100% specificity and 100% PPV for smear-positive specimens but 98% specificity and 60% PPV for smear-negative specimens. In conclusion, the Xpert assay showed performance that was slightly inferior to that of the Cobas assay but seems useful for the rapid detection of M. tuberculosis , considering that it was performed without laborious and time-consuming decontamination and concentration procedures.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3