Screening of Urine Samples by Flow Cytometry Reduces the Need for Culture

Author:

Jolkkonen Santra1,Paattiniemi Eeva-Liisa2,Kärpänoja Pauliina1,Sarkkinen Hannu1

Affiliation:

1. Department of Clinical Microbiology

2. Department of Clinical Chemistry, Päijät-Häme Social and Health Care Group, Center of Medical Services, Lahti, Finland

Abstract

ABSTRACT Urine samples constitute a large proportion of samples tested in clinical microbiology laboratories. Culturing of the samples is fairly time- and labor-consuming, and most of the samples will yield no growth or insignificant growth. We analyzed the feasibility of the flow cytometry-based UF-500i instrument (Sysmex, Japan) to screen out urine samples with no growth or insignificant growth and reduce the number of samples to be cultured. A total of 1,094 urine specimens sent to our laboratory for culture during 4 months in the spring of 2009 in Lahti, Finland, were included in the study. After culture, all samples were analyzed with the Sysmex UF-500i for bacterial and leukocyte (white blood cell [WBC]) counts. Youden index and closest (0,1) methods were used to determine the cutoff values for bacterial and WBC counts in culture-positive and -negative groups. By flow cytometry, samples considered positive for UTI in culture had bacterial and WBC values that were significantly higher than those for samples considered negative. The flow cytometric screening worked best when both bacterial counts and WBC counts were used with age- and gender-specific cutoff values for all patient groups, excluding patients with urological disease or anomaly. By use of these cutoff values, 5/167 (3.0%) of culture-positive samples were missed by UF-500i and the percentage of samples that did not need to be cultured was 64.5%. Use of the UF-500i instrument is a reliable method for screening out a major part of the UTI-negative samples, significantly diminishing the amount of work required in the microbiology laboratory.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference25 articles.

1. Akobeng, A. K. 2007. Understanding diagnostic tests 3: receiver operating characteristic curves. Acta Paediatr. 96 : 644-647.

2. Ben-Ezra, J., L. Bork, and R. McPherson. 1998. Evaluation of the Sysmex UF-100 automated urinalysis analyzer. Clin. Chem. 44 : 92-95.

3. Brilha, S., H. Proença, J. M. Cristino, and T. Hänscheid. 2010. Use of flow cytometry (Sysmex® UF-100) to screen for positive urine cultures: in search for ideal cut-off. Clin. Chem. Lab. Med. 48 : 289-292.

4. Devillé, W. L. J. M., J. C. Yzermans, N. P. van Duijn, P. D. Bezemer, D. A. W. M. van der Windt, and L. M. Bouter. 2004. The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy. BMC Urol. 4 : 4.

5. dos Santos, J. C., L. P. Weber, and L. R. R. Perez. 2007. Evaluation of urinalysis parameters to predict urinary-tract infection. Braz. J. Infect. Dis. 11 : 479-481.

Cited by 92 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3