First Evaluation of the WASP, a New Automated Microbiology Plating Instrument

Author:

Bourbeau Paul P.1,Swartz Brandi Lynn1

Affiliation:

1. Geisinger Medical Center, Danville, Pennsylvania

Abstract

ABSTRACT Many laboratories are experiencing growing shortages of trained microbiology technologists and technicians. Consequently, there is considerable interest in new automation that could potentially lessen labor demands for specimen processing. In this study, we present the first published evaluation of a new microbiology instrument, the Walk Away Specimen Processor (WASP), manufactured by Copan, Inc., in which we evaluated cross-contamination, the accuracy of plating, and the quality of the results. The absence of cross-contamination was demonstrated by plating a total of 200 alternating inoculated and sterile specimen tubes. The ability of the WASP to subculture enrichment broths was evaluated with 106 Lim broth specimens, with the results being identical to those obtained by testing by routine methods. Plating of urine specimens with the WASP was compared to plating with the Dynacon Inoculab instrument. Three hundred specimens were plated in duplicate on both instruments with 1-μl loops, and 293 specimens were plated in duplicate on both instruments with 10-μl loops. The results of duplicate plating with the same instrument (replicate plating) and of the consensus agreement between the two instruments were compared. The replicate plating results were comparable for both instruments, while the WASP had more specimens with significant results than the Inoculab with the 1-μl loop only. Lastly, for the plating of 113 specimens in ESwab tubes, the manual method and WASP plating each yielded 90 potential pathogens. In summary, we report the first evaluation of a new microbiology specimen-plating instrument, the WASP, which offers opportunities for the automated plating of microbiology specimens to an extent that has not been possible to date.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference7 articles.

1. Accuracy of calibrated-loop transfer

2. Evaluation of an Automated Instrument for Inoculating and Spreading Samples onto Agar Plates

3. Abstr. 108th Gen. Meet. Am. Soc. Microbiol. abstr. 169. 2008

4. Kass, E. 1956. Asymptomatic infections of the urinary tract. Trans. Assoc. Am. Phys.69:56-63.

5. Abstr. 102nd Gen. Meet. Am. Soc. Microbiol. abstr. 81. 2002

Cited by 45 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献