Abstract
Therapeutic concentrations of amphotericin B in serum were measured by reversed-phase liquid chromatography with detection at 386 nm. Complete recovery of the drug and the internal standard from a 1-ml serum sample was achieved by pretreating the sample with guanidine hydrochloride and extracting it with a disposable reversed-phase phenyl extraction column. The method was sensitive to 0.005 micrograms of amphotericin B per ml and linear to at least 5 micrograms/ml. Coefficients of variation were 4.8% within-run and 6.3% between-run.
Publisher
American Society for Microbiology
Subject
Infectious Diseases,Pharmacology (medical),Pharmacology
Reference11 articles.
1. Asher I. M. G. Schwartzman and the U.S. Antibiotics Standards Research Group. 1977. Amphotericin B p. 1-42. In K. Florey (ed.) Analytical profiles of drug substances vol. 6. Academic Press Inc. New York.
2. Amphotericin B pharmacokinetics in humans;Atkinson A. J.;Antimicrob. Agents Chemother.,1978
3. Clayton Y. 1978. Yeasts and other fungi p. 120-123. In D. S. Reeves I. Phillips J. D. Williams and R. Wise (ed.) Laboratory methods in antimicrobial chemotherapy. Churchill Livingstone Ltd. Edinburgh.
4. Excretion pathways of amphotericin B;Craven P. C.;J. Infect. Dis.,1979
5. Technical considerations in the use of "highperformance;Giese R. W.;Clin. Chem.,1983
Cited by
25 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献