Comparison of Three Commercially Available Peptide-Based Immunoglobulin G (IgG) and IgA Assays to Microimmunofluorescence Assay for Detection of Chlamydia trachomatis Antibodies

Author:

Morré Servaas A.1,Munk Christian2,Persson Kenneth3,Krüger-Kjaer Susanne2,van Dijk Rogier1,Meijer Chris J. L. M.1,van den Brule Adriaan J. C.1

Affiliation:

1. Department of Pathology, Section of Molecular Pathology, Vrije Universiteit Medical Center, Amsterdam, The Netherlands

2. Danish Cancer Society, Institute of Cancer Epidemiology, Copenhagen, Denmark

3. Department of Clinical Microbiology, Malmö University Hospital, Malmö, Sweden

Abstract

ABSTRACT Three commercially available, peptide-based enzyme-linked immunosorbent assay (ELISA) systems (Chlamydia trachomatis IgG and IgA EIA [CT-EIA; Labsystems OY, Helsinki, Finland], SeroCT IgG and IgA [SeroCT; Savyon Diagnostics Ltd., Ashdod, Israel], and Chlamydia trachomatis IgG and IgA pELISA [CT pELISA; Medac, Wedel, Germany]) were evaluated for the detection of serum immunoglobulin G (IgG) and IgA antibodies specific for Chlamydia trachomatis and compared to the “gold standard” assay, the microimmunofluorescence (MIF) assay. Serological responses were analyzed in 149 women aged 20 to 30 years. Cervical swabs obtained from these women were examined for C. trachomatis by PCR, and 43 were found to be positive. The overall seroprevalence rates detected by CT-EIA, SeroCT, CT pELISA, and the MIF assay were 42, 42, 35, and 39%, respectively, for IgG and 7, 7, 3, and 7%, respectively, for IgA. The IgG seroprevalence rates for the PCR-positive women were two to three times higher than those for the PCR-negative women, i.e., 72 versus 29%, 72 versus 29%, 47 versus 26%, and 74 versus 25% for CT-EIA, SeroCT, CT pELISA, and the MIF assay, respectively. After discrepancy analysis, the sensitivity, specificity, positive predictive value, and negative predictive value were calculated for the IgG assays; for CT-EIA they were 84.7, 98.6, 98.4, and 86.7%, respectively; for CT pELISA they were 71.4, 97.3, 96.2, and 78.3%, respectively; for SeroCT they were 84.7, 98.6, 98.4, and 86.3%, respectively; and for the MIF assay they were 79.2, 83.1, 98.3, and 83.1%, respectively. In conclusion, these peptide-based ELISA systems for the serological detection of C. trachomatis infection performed as well as the MIF assay. Since these tests are less time-consuming, less expensive, and easier to perform than the MIF assay, they might be useful in the serodiagnosis of chlamydial infection.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 80 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3