Affiliation:
1. Department of Microbiology, Faculty of Medicine, Kuwait University, Kuwait
Abstract
ABSTRACT
Conventional light microscopy has been the established method for malaria diagnosis. However, recently several nonmicroscopic rapid diagnostic tests have been developed for situations in which reliable microscopy may not be available. This study was conducted to evaluate the diagnostic performance of a recently introduced ICT Malaria Pf/Pv test. This assay detects
Plasmodium falciparum
histidine-rich protein 2 antigen (PfHRP-2) for
P. falciparum
diagnosis and pan-malarial antigen for
P. vivax
diagnosis. In this study we compared the performance of ICT Malaria Pf/Pv with microscopy of Giemsa-stained blood films and with an OptiMAL test that detects
Plasmodium
lactate dehydrogenase (pLDH) antigen. A total of 750 clinically suspected malaria patients were examined at local health centers in Kuwait. Both the antigen tests had a high degree of specificity (>98%) for detection of malaria infection. However, they were less sensitive than microscopy. Compared with microscopy the ICT Malaria PF/pf test failed to detect malaria infection in 93 (34%) of 271 malaria patients (11% of patients with
P. falciparum
and 37% of patients with
P. vivax
) and the OptiMAL test failed to detect malaria infection in 41 (15%) of 271 malaria patients (7% of patients with
P. falciparum
and 13% of patients with
P. vivax
). The sensitivities of the ICT Malaria Pf/Pv and OptiMAL tests for detection of
P. falciparum
infection were 81 and 87%, and those for detecting
P. vivax
were 58 to 79%, respectively. The sensitivity of the ICT Malaria Pf/Pv and OptiMAL tests decreased significantly to 23 and 44%, respectively, at parasite densities of <500/μl. Both of the tests also produced a number of false-positive results. Overall, the performance of the OptiMAL test was better than that of the ICT Malaria Pf/Pv test. However, our results raise particular concern over the sensitivity of the ICT Malaria Pf/Pv test for detection of
P. vivax
infection. Further developments appear necessary to improve the performance of the ICT Malaria Pf/Pv test.
Publisher
American Society for Microbiology
Reference32 articles.
1. Anonymous. 1996. A rapid dipstick antigen capture assay for the diagnosis of falciparum malaria. W. H. O. informal consultation on recent advances in diagnostic techniques and vaccines for malaria. Bull. W. H. O.74:47-54.
2. Beadle, C., G. W. Long, W. R. Weiss, P. D. McElroy, S. M. Maret, A. J. Oloo, and S. L. Hoffman. 1994. Diagnosis of malaria by detection of Plasmodium falciparum HRP-2 antigen with a rapid dipstick antigen-capture assay. Lancet343:564-568.
3. Cho-Min-Naing, and M. L. Gatton. 2002. Performance appraisal of rapid on-site malaria diagnosis (ICT Malaria Pf/Pv test) in relation to human resources at village level in Myanmar. Acta Trop.81:13-19.
4. Cooke, A., H., P. L. Chiodini, T. Doherty, A. H. Moody, J. Ries, and M. Pinder. 1999. Comparison of a parasite lactate dehydrogenase-based immunochromatographic antigen detection assay (OptiMAL) with microscopy for the detection of malaria parasites in human blood samples. Am. J. Trop. Med. Hyg.60:173-176.
5. Durrheim, D., N., J. J. P. la Grange, J. Govere, and N. M. Mngomezulu. 1998. Accuracy of a rapid immunochromatographic card test for Plasmodium falciparum in a malaria control programme in South Africa. Trans. R. Soc. Trop. Med. Hyg.92:32-33.
Cited by
82 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献