Controlled Comparative Evaluation of BacT/Alert FAN and ESP 80A Aerobic Media as Means for Detecting Bacteremia and Fungemia

Author:

Doern Gary V.1,Barton Ann1,Rao Sudah1

Affiliation:

1. University of Massachusetts Medical Center, Worcester, Massachusetts 01655

Abstract

ABSTRACT During a one-year period, a total of 6,305 blood cultures were processed in a tertiary-care teaching hospital; 6 to 12 ml of blood was inoculated into both a BacT/Alert Fan aerobic bottle and an ESP 80A aerobic bottle. The FAN aerobic bottle contains an antimicrobial-absorbing material; the 80A aerobic bottle does not. Bottles were processed on their respective continuous-monitoring blood culture instruments for up to five days of incubation. Four hundred thirty-three cultures (6.9%) representing 301 septic episodes in 235 different patients yielded 490 bacteria or yeasts thought to be clinically significant. Two hundred seventy-five of the 433 presumed clinically significant positive cultures (63.5%) representing 195 septic episodes and yielding 301 isolates were positive in both FAN and 80A bottles. One hundred nine significant positive cultures (25.2%) (i.e., cultures positive with an organism judged to be of probable clinical significance) from 70 septic episodes yielded 126 isolates only in FAN bottles. Conversely, the 80A bottle was exclusively positive in 49 instances (11.3%), representing 36 septic episodes and yielding 63 isolates. The higher rates of significant positive blood cultures, numbers of septic episodes documented, and numbers of isolates recovered in FAN bottles versus 80A bottles were all statistically significant ( P < 0.05). Enhanced rates of detection of presumed clinically significant isolates in FAN bottles were largely accounted for by Staphylococcus aureus , members of the Enterobacteriaceae , and non- Pseudomonas aeruginosa miscellaneous gram-negative bacilli from patients receiving antimicrobial therapy at the time blood cultures were obtained. Enhanced recovery of one organism group, the β-hemolytic streptococci, occurred in 80A. With one exception, detection times were essentially equivalent in the two systems. The single exception pertained to streptococci and enterococci, which were recovered significantly faster in 80A bottles. Three hundred thirty-eight of the 6,305 blood cultures evaluated in this study (5.4%) were judged likely to be contaminated. The percentages of probable contaminated cultures were as follows: 26.6% FAN and 80A; 42.3% FAN only; 31.1% 80A only ( P < 0.05). Finally, the instrument false-positive rates for the two systems were 0.7% with FAN and 3.0% with 80A ( P < 0.05). We conclude that while contamination rates were slightly higher with FAN than with 80A, use of FAN aerobic bottles in conjunction with the BacT/Alert system will yield significantly higher numbers of clinically significant blood culture isolates than 80A bottles and the ESP system. Furthermore, this enhanced detection is most conspicuous in patients receiving antimicrobial therapy at the time blood cultures are performed, probably due to the presence of an antimicrobial-absorbing material in FAN aerobic bottles.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference25 articles.

1. Enhanced detection of bacteremia with a new BACTEC resin blood culture medium

2. Clinical comparison of difco ESP, Wampole isolator, and Becton Dickinson Septi-Chek aerobic blood culturing systems

3. Detection of bacteremia in patients receiving antimicrobial therapy: an evaluation of the antimicrobial removal device and 16B medium

4. Doern G. V. Barton A. Rao S. Comparison of the BacT/Alert aerobic FAN medium and Difco ESP aerobic medium as means for detecting bacteremia and fungemia abstr. C-433 Abstracts of the 97th General Meeting of the American Society for Microbiology 1997. 1997 195 American Society for Microbiology Washington D.C

5. Clinical comparison of the BACTEC 9000 standard anaerobic/F and lytic/F blood culture media;Hollick G. E.;Diagn. Microbiol. Infect. Dis.,1996

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Automated Blood Cultures;Advanced Techniques in Diagnostic Microbiology;2018

2. The bioMérieux BacT/Alert: Automation at Last in the Black Box;The Dark Art of Blood Cultures;2017-08-24

3. Commercial Blood Culture Systems and Methods;Manual of Commercial Methods in Clinical Microbiology;2016-04-01

4. Laboratory Detection of Bacteremia and Fungemia;Manual of Clinical Microbiology;2015-05-26

5. Identification of the most common pathogenic bacteria in patients with suspected sepsis by multiplex PCR;The Journal of Infection in Developing Countries;2014-04-15

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3