Affiliation:
1. Cell-Free Science and Technology Research Center
2. Department of Parasitology, Kangwon National University College of Medicine, Chunchon 200-701, Korea
3. Department of Entomology, Armed Forces Research Institute of Medical Sciences, Bangkok 10400, Thailand
4. Vector Borne Disease Training Center, Pra Budhabat, Saraburi 18120, Thailand
5. Venture Business Laboratory, Ehime University, Matsuyama, Ehime 790-8577, Japan
Abstract
ABSTRACT
Loop-mediated isothermal amplification (LAMP), a novel nucleic acid amplification method, was developed for the clinical detection of four species of human malaria parasites:
Plasmodium falciparum
,
P. vivax
,
P. malariae
, and
P. ovale
. We evaluated the sensitivity and specificity of LAMP in comparison with the results of microscopic examination and nested PCR. LAMP showed a detection limit (analytical sensitivity) of 10 copies of the target 18S rRNA genes for
P. malariae
and
P. ovale
and 100 copies for the genus
Plasmodium
,
P. falciparum
, and
P. vivax
. LAMP detected malaria parasites in 67 of 68 microscopically positive blood samples (sensitivity, 98.5%) and 3 of 53 microscopically negative samples (specificity, 94.3%), in good agreement with the results of nested PCR. The LAMP reactions yielded results within about 26 min, on average, for detection of the genus
Plasmodium
, 32 min for
P. falciparum
, 31 min for
P. vivax
, 35 min for
P. malariae
, and 36 min for
P. ovale
. Accordingly, in comparison to the results obtained by microscopy, LAMP had a similar sensitivity and a greater specificity and LAMP yielded results similar to those of nested PCR in a shorter turnaround time. Because it can be performed with a simple technology, i.e., with heat-treated blood as the template, reaction in a water bath, and inspection of the results by the naked eye because of the use of a fluorescent dye, LAMP may provide a simple and reliable test for routine screening for malaria parasites in both clinical laboratories and malaria clinics in areas where malaria is endemic.
Publisher
American Society for Microbiology
Reference30 articles.
1. Coleman, R. E., J. Sattabongkot, S. Promstaporm, N. Maneechai, B. Tippayachai, A. Kengluecha, N. Rachapaew, G. Zollner, R. S. Miller, J. A. Vaughan, K. Thimasarn, and B. Khuntirat. 2006. Comparison of PCR and microscopy for the detection of asymptomatic malaria in a Plasmodium falciparum/vivax endemic area in Thailand. Malar. J.14:121.
2. Use of Loop-Mediated Isothermal Amplification of the IS
900
Sequence for Rapid Detection of Cultured
Mycobacterium avium
subsp.
paratuberculosis
3. Ferro, B. E., I. J. Gonzalez, F. Carvajal, G. I. Palma, and N. G. Saravia. 2002. Performance of OptiMAL in the diagnosis of Plasmodium vivax and Plasmodium falciparum infections in a malaria referral center in Colombia. Mem. Inst. Oswaldo Cruz97:731-735.
4. Hanscheid, T., and M. P. Grobusch. 2002. How useful is PCR in the diagnosis of malaria? Trends Parasitol.18:395-398.
5. Molecular Evidence of Infections with
Babesia gibsoni
Parasites in Japan and Evaluation of the Diagnostic Potential of a Loop-Mediated Isothermal Amplification Method
Cited by
237 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献