Multilaboratory Comparison of Hepatitis C Virus Viral Load Assays

Author:

Caliendo A. M.1,Valsamakis A.2,Zhou Y.3,Yen-Lieberman B.4,Andersen J.3,Young S.5,Ferreira-Gonzalez A.6,Tsongalis G. J.7,Pyles R.8,Bremer J. W.9,Lurain N. S.9

Affiliation:

1. Emory University School of Medicine, Atlanta, Georgia

2. The Johns Hopkins Medical Institutions, Baltimore, Maryland

3. Harvard School of Public Health, Boston, Massachusetts

4. Cleveland Clinic Foundation, Cleveland, Ohio

5. Tricore Reference Laboratories, Albuquerque, New Mexico

6. Virginia Commonwealth University, Richmond, Virginia

7. Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire

8. University of Texas Medical Branch, Galveston, Texas

9. Division of AIDS Viral Quality Assurance Laboratory Viral Quality Assessment Laboratory, Rush University Medical Center, Chicago, Illinois

Abstract

ABSTRACT We report a multilaboratory evaluation of hepatitis C virus (HCV) viral load assays to determine their linear range, reproducibility, subtype detection, and agreement. A panel of HCV RNA samples ranging in nominal concentration from 1.0 to 7.0 log 10 IU/ml was constructed by diluting a clinical specimen (genotype 1b). Replicates of the panel were tested in multiple laboratories using the Abbott TaqMan analyte-specific reagent (Abbott reverse transcription-PCR [RT-PCR]), Roche TaqMan RUO (Roche RT-PCR), Roche Amplicor Monitor HCV 2.0 (Roche Monitor), and Bayer VERSANT HCV RNA 3.0 (Bayer bDNA) assays. Bayer bDNA-negative specimens were tested reflexively using the Bayer VERSANT HCV RNA qualitative assay (Bayer TMA). Abbott RT-PCR and Roche RT-PCR detected all 28 replicates with a concentration of 1.0 log 10 IU/ml and were linear to 7.0 log 10 IU/ml. Roche Monitor and Bayer bDNA detected 27 out of 28 and 13 out of 28 replicates, respectively, of 3.0 log 10 IU/ml. Bayer TMA detected all seven replicates with 1.0 log 10 IU/ml. Bayer bDNA was the most reproducible of the four assays. The mean viral load values for panel members in the linear ranges of the assays were within 0.5 log 10 for the different tests. Eighty-nine clinical specimens of various genotypes (1 through 4) were tested in the Bayer bDNA, Abbott RT-PCR, and Roche RT-PCR assays. For Abbott RT-PCR, mean viral load values were 0.61 to 0.96 log 10 greater than the values for Bayer bDNA assay for samples with genotype 1, 2, or 3 samples and 0.08 log 10 greater for genotype 4 specimens. The Roche RT-PCR assay gave mean viral load values that were 0.28 to 0.82 log 10 greater than those obtained with the Bayer bDNA assay for genotype 1, 2, and 3 samples. However, for genotype 4 samples the mean viral load value obtained with the Roche RT-PCR assay was, on average, 0.15 log 10 lower than that of the Bayer bDNA. Based on these data, we conclude that the sensitivity and linear range of the Abbott and Roche RT-PCR assays enable them to be used for HCV diagnostics and therapeutic monitoring. However, the differences in the viral load values obtained with the different assays underscore the importance of using one assay when monitoring response to therapy.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 49 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3