The method for design of electromagnetic hybrid active-passive shielding by overhead power lines magnetic field

Author:

Kuznetsov B. I.ORCID,Nikitina T. B.ORCID,Bovdui I. V.ORCID,Chunikhin K. V.ORCID,Kolomiets V. V.ORCID,Kobylianskyi B. B.ORCID

Abstract

Aim. Development of the method for designing electromagnetic hybrid active-passive shield, consisting from active and multy-circuit passive parts, which is characterized by increased effectiveness of reducing the industrial frequency magnetic field created by two-circuit overhead power lines in residential buildings. Methodology. The designing problem of electromagnetic hybrid active-passive shield including robust system of active shielding and multy-circuit passive shield of initial magnetic field comes down to a solution of the multy-criteria two-player zero-sum antagonistic game. The game payoff vector calculated based on the finite element calculations system COMSOL Muliphysics. The game solution calculated based on the particles multyswarm optimization algorithms. Results. During the design of the electromagnetic hybrid active-passive shield the coordinates of the spatial arrangement of 11 circuits passive shield and the coordinates of the spatial location of one compensation winding, as well as the current and phase in this winding of the active shielding system are calculated. The results of theoretical and experimental studies of hybrid active and multy-circuit passive shield by magnetic field in residential building from two-circuit power transmission line with a «Barrel» type arrangement of wires presented. Originality. For the first time the method for designing hybrid active and multy-circuit passive shield, consisting from active and multy-circuit passive parts, which is characterized by increased effectiveness of reducing the magnetic field of industrial frequency created by two-circuit overhead power lines in residential buildings is developed. Practical value. Based on results of calculated study the shielding efficiency of the initial magnetic field what is confirmed by experimental studies determined that shielding factors whith only multy-circuit passive shield is more 1.2 units, whith only active shield is more 4 units and with electromagnetic hybrid active-passive shield is more 6.2 units. It is shown the possibility to reduce the level of magnetic field induction in residential building from two-circuit power transmission line with a «Barrel» type arrangement of wires by means of electromagnetic hybrid active shielding with single compensating winding and multy-circuit passive shielding with 11 circuit passive shield to 0.5 μT level safe for the population. References 51, figures 17.

Publisher

National Technical University Kharkiv Polytechnic Institute

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3