Multi-angle in situ dynamic light scattering at a neutron spin echo spectrometer

Author:

Vögl F.12ORCID,Balacescu L.13ORCID,Holderer O.1ORCID,Pasini S.1ORCID,Staringer S.1,Brandl G.1ORCID,Ossovyi V.1,Feilbach H.4,Müller-Buschbaum P.25ORCID,Stadler A. M.46ORCID,Fitter J.37ORCID,Schrader T. E.1ORCID

Affiliation:

1. Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science (JCNS) at Heinz Maier-Leibnitz Zentrum (MLZ) 1 , 85748 Garching, Germany

2. Technical University of Munich, TUM School of Natural Sciences, Department of Physics, Chair for Functional Materials 2 , James-Franck-Str. 1, 85748 Garching, Germany

3. RWTH Aachen, Physikalisches Institut (IA), AG Biophysik 3 , 52074 Aachen, Germany

4. Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science (JCNS-1) and Institute of Biological Information Processing (IBI-8) 4 , 52425 Jülich, Germany

5. Technische Universität München, MLZ 5 , Lichtenbergstr. 1, 85748 Garching, Germany

6. RWTH Aachen University, Institute of Physical Chemistry 6 , Landoltweg 2, 52056 Aachen, Germany

7. Forschungszentrum Jülich GmbH, Institute of Biological Information Processing (IBI-6) 7 , 52425 Jülich, Germany

Abstract

A new sample environment, called Bio-Oven, has been built for the Neutron Spin Echo (NSE) Spectrometer J-NSE Phoenix. It provides active temperature control and the possibility to perform Dynamic Light Scattering (DLS) measurements during the neutron measurement. DLS provides diffusion coefficients of the dissolved nanoparticles, and thus one can monitor the aggregation state of the sample on a time scale of minutes during the spin echo measurement times on the order of days. This approach helps to validate the NSE data or to replace the sample when its aggregation state influences the spin echo measurement results. The new Bio-Oven is an in situ DLS setup based on optical fibers decoupling the free space optics around the sample cuvette in a lightproof casing from the laser sources and the detectors. It collects light from three scattering angles simultaneously. Six different values of momentum transfer can be accessed by switching between two different laser colors. Test experiments were performed with silica nanoparticles with diameters ranging from 20 nm up to 300 nm. Their hydrodynamic radii were determined from DLS measurements and compared with the ones obtained by a commercial particle sizer. It was demonstrated that also the static light scattering signal can be processed and gives meaningful results. The protein sample apomyoglobin was used for a long-term test and in a first neutron measurement using the new Bio-Oven. The results prove that the aggregation state of the sample can be followed using in situ DLS along with the neutron measurement.

Funder

Bundesministerium für Bildung und Forschung

Publisher

AIP Publishing

Subject

Instrumentation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3