Affiliation:
1. Key Laboratory of Materials Modification by Laser, Ion, and Electron Beams (Dalian University of Technology), Ministry of Education, School of Physics , Dalian 116024, People's Republic of China
Abstract
The influence of the cylindrical exposed electrode diameter on distribution and attenuation of the surface charge in surface dielectric barrier discharges is experimentally investigated using the Pockels effect of the Bi12SiO20 crystal. For the actuator with the smaller exposed electrode diameter, more positive charges accumulate closer to the exposed electrode after positive half periodic discharge, while the quantity of positive charges deposited on the surface in a discharge period at the same distance away from the exposed electrode is smaller. At the same time, the smaller the exposed electrode diameter is, the shorter decay time the positive charge filament needs. Combined with thrust generation of actuators, it can be indicated that a positive residual surface charge closer to the exposed electrode may play a more crucial role in the discharge and consequent thrust than one far away from the exposed electrode does. Also, the effect on the discharge of the positive residual surface charge may be greater than that of the negative residual surface charge. More explorations of the residual surface charge have been done by selectively enhancing the discharge of the actuator with a 10 μm exposed electrode using the pulse-AC dual power supply, drawing the same conclusions.
Funder
National Natural Science Foundation of China
Subject
General Physics and Astronomy
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献