Experimental concept validation of a proton therapy range verification system using scattered proton measurements

Author:

Sato S.1ORCID,Yokokawa H.1,Sagisaka M.1ORCID,Okazaki Y.1,Iwashita R.1,Yoshida S.1,Tanaka K. S.1ORCID,Yamamoto S.1,Yamashita T.2ORCID,Kobashi Y.2ORCID,Kataoka J.1ORCID

Affiliation:

1. Faculty of Science and Engineering, Waseda University 1 , Shinjuku, Tokyo 169-8555, Japan

2. Division of Medical Physics, Kobe Proton Center 2 , Kobe, Hyogo 650-0047, Japan

Abstract

In recent years, the application of positron emission tomography (PET) for the dose range verification of proton therapy has been proposed. However, the positron distribution is determined by the nuclear reaction cross section; hence, PET may not accurately reflect the dose range primarily influenced by ionization. Consequently, a proton dose range verification system based on scattered proton measurements has been suggested owing to the similarity in the reaction cross section between Rutherford scattering and ionization. While previous investigations have only verified the feasibility of dose range estimation through simple simulations, the objective of this study is to demonstrate this feasibility through experimental investigation. In this paper, we established an experimental framework for capturing scattered protons and introduced an algorithm that compares measured signal patterns with a reference database to estimate the dose range. A therapeutic beam was irradiated onto the abdominal region of a human phantom, and scattered protons were measured using scintillation detectors placed on the phantom surface. Consequently, the dose range was estimated with error margins of 4.22 ± 3.68 and 0.60 ± 1.03 mm along the beam axis and perpendicular directions to the Bragg peak, respectively. While providing the same level of Bragg peak positioning accuracy as conventional methods, our system features small size, cost-effectiveness, and system simplicity. One notable limitation of our method is the challenge in achieving precise detector positioning, which is crucial for accurate dose range estimation. Future research will focus on improving detector-position accuracy and exploring advanced algorithms for signal analysis to further refine dose range estimations.

Funder

Japan Science and Technology Agency

Japan Society for the Promotion of Science

Publisher

AIP Publishing

Reference62 articles.

1. Radiological use of fast protons;Radiology,1946

2. Pituitary irradiation with high-energy proton beams a preliminary report;Cancer Res.,1958

3. Is it possible to verify directly a proton-treatment plan using positron emission tomography?;Radiother. Oncol.,1993

4. Proton dose monitoring with PET: Quantitative studies in Lucite;Phys. Med. Biol.,1996

5. Potential application of PET in quality assurance of proton therapy;Phys. Med. Biol.,2000

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3