Review of current incidents and risk calculations used in the Royal College of Australasian Pathologists Key Incident Management and Monitoring Systems - a system that could be used by all Australasian medical laboratories, and easily adapted to worldwide use

Author:

Whiley Michael1,Pope Belinda2,Badrick Tony3,Gay Stephanie3

Affiliation:

1. Medical Services, NSW Health Pathology, Sydney, Australia

2. Quality Department, Douglass Hanly Moir, Sydney, Australia

3. Key Incident Management and Monitoring System (KIMMS) program, Royal College of Pathologists of Australasia Quality Assurance Programs, Sydney, Australia

Abstract

The Royal College of Pathologists of Australasia Quality Assurance Programs (RCPAQAP) Key Incident Monitoring and Management Systems (KIMMS) program has found that some existing Quality Indicators are too broad or not well defined. The risk matrix in use does not allow changes in incident Detection or Probability. In 2020, a review was performed: what issues should KIMMS include as Key Incidents and how could risk measurement be improved? Twenty-seven networked and stand-alone laboratories enrolled in KIMMS during 2020 were surveyed on 45 current and new indicators of risk in the total testing process. They were asked which indicators they considered were significant in causing patient harm. Existing risk matrices in use by members of the KIMMS Advisory Committee laboratories were reviewed regarding their size or structure (3x3 or 5x5) and the descriptions of consequences and probability. Thirteen participants indicated 21 indicators should be monitored, and the KIMMS Advisory committee added a further 13 (11 from the remaining 24 and 2 new). Of the five risk matrices reviewed, all consistently used a 5x5 matrix to estimate Consequences vs Probability of harm. The KIMMS advisory committee added a third parameter to the calculation of Risk, Detectability. All 34 pre- and post- indicators should be monitored, covering all aspects of the total testing cycle other than analytical. The risk measurement can be improved by introducing a 5x5 risk matrix to evaluate harm (consequences x probability) and then evaluating risk by adding detectability; risk equals harm x detectability.

Publisher

Croatian Society for Medical Biochemistry and Laboratory Medicine

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3