Affiliation:
1. Laboratory for Zoonoses and Food Microbiology, National Institute of Public Health, P.O. Box 1, 3720 BA Bilthoven, The Netherlands
Abstract
ELISA (enzyme-linked immunosorbent assay) was employed to demonstrate staphylococcal enterotoxins A, B, C and E (SEA, SEB, SEC and SEE) in minced meat (50% beef/50% pork). For unheated minced meat, extraction of the sample with an equal amount of distilled water at pH 4.5 and a subsequent concentration (10-fold) of the extract, readjusted to pH 7.2, was sufficient to detect less than 0.5 μg of SE per 100 g of product. The extraction procedure gave 40–80% recovery of the toxin, and using the ELISA system neither false-positive nor false-negative results were obeserved. Using the just mentioned extraction procedure, recovery of SE that had been heated in minced meat was low (0.14% for SEB). It was demonstrated that components extracted by heating (among others, gelatin) present in minced meat caused immunological inactivation of SEB, SEC and SEE during heating. From monkey-feeding tests it became clear that the immunological inactivation of SEB in gelatin by heating was accompanied by biological inactivation.
Publisher
International Association for Food Protection
Subject
Microbiology,Food Science
Cited by
42 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献