Accuracy of Intraocular Lens Power Calculation Formulas in Patients With Multifocal Intraocular Lens Implantation With Optic Capture in Berger Space for Pediatric Cataract

Author:

Wang Menghan,Li Dongfang,Fan Zheng,Zhang Jing,Zhou Jinyan,Huang Yusen

Abstract

Purpose: To assess the accuracy of intraocular lens (IOL) calculation formulas in pediatric patients with multifocal IOL implantation with optic capture in Berger space. Methods: This prospective observational study enrolled 68 children (101 eyes), aged 3 to 14 years, who received multifocal IOL (Tecnis ZMB00; Abbott Medical Optics) implantation with optic capture in Berger space from June 2019 to June 2020 in Qingdao Eye Hospital. Ocular biometry was performed using the IOLMaster 700 (Carl Zeiss Meditec). The IOL power and intended postoperative refraction were calculated using the Hoffer Q, Barrett Universal II, Holladay, Holladay2, SRK/T, Haigis, and SRKII formulas. The refractive state of patients, prediction error, and absolute prediction error were evaluated. Results: The mean absolute error of the formulas was significantly different (0.49 diopters [D], Hoffer Q; 0.52 D, Barrett Universal II; 0.47 D, Holladay; 0.54 D, Holladay2; 0.52 D, SRK/T; 0.67 D, Haigis; 0.99 D, SRKII; P < .001). However, the Hoffer Q, Barrett Universal II, Holladay, Holladay2, and SRK/T formulas had a similar accuracy in predicting refractive error within ±0.50 D (62.4%, 59.4%, 62.4%, 62.4%, and 58.4%). There was a trend toward a greater prediction error in eyes with a shorter axial length (≤ 22 mm) or a steeper cornea (> 43.50 D), for which the Hoffer Q and Holladay2 formulas were more accurate. When the axial length was greater than 22 mm or the corneal curvature was 43.50 D or less, the Holladay, Hoffer Q, and Barrett Universal II formulas were more accurate. Conclusions: For patients with pediatric cataract treated with multifocal IOL implantation with optic capture in Berger space, the Hoffer Q, Barrett Universal II, Holladay, Holladay2, and SRK/T formulas performed better than the other formulas. [ J Pediatr Ophthalmol Strabismus . 2023;60(2):139–146.]

Publisher

SLACK, Inc.

Subject

Ophthalmology,General Medicine,Pediatrics, Perinatology and Child Health

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com