Influence of observers, threshold values, and measurement methods on volumetric analysis of cerebral aneurysms with three-dimensional rotational angiography

Author:

Cho Won-Sang,Shin Dong Hoon,Lee Joongyub,Lee Seung Jin

Abstract

IntroductionExact measurements of cerebral aneurysms are important in terms of their treatment. However, there is no definitive way to estimate the exact volume of an aneurysm. Our aim was to compare aneurysm volume measured under different conditions: threshold values, observers, and measurement methods.Methods40 aneurysms and 7 phantom models were included in the study. Three-dimensional rotational angiography was used, and volumes were compared based on the following factors: two methods (two-dimensional formula calculation and three-dimensional software measurement); three observers; and three threshold values for imaging. In addition, in the phantom models, measured volumes were compared with real volumes. The consistency of the volume measurements under different conditions was assessed using the intraclass correlation coefficient (ICC).ResultsThe consistency of the measured volumes was excellent in both the patient aneurysms (ICC >0.98) and phantom models (ICC >0.95), irrespective of the influencing factors. Median volume differences were small for observers, threshold values, and methods. When the measured and real volumes of the phantom models were compared, the software measurement achieved the highest reproducibility for real volumes compared with the formula calculation (ICC=0.86–0.93 vs 0.71–0.80).ConclusionsMeasurement of aneurysm volume showed high agreement within each influencing factor, such as methods, observers, and threshold values.

Publisher

BMJ

Subject

Neurology (clinical),General Medicine,Surgery

Reference16 articles.

1. Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms;Hochmuth;AJNR,2002

2. Reappraisal of anatomic outcome scales of coiled intracranial aneurysms in the prediction of recanalization;Lee;J Korean Neurosurg Soc,2013

3. Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils;Sluzewski;Radiology,2004

4. Intracranial aneurysms: treatment with bare platinum coils- aneurysm packing, complex coils, and angiographic recurrence;Piotin;Radiology,2007

5. Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms;Tamatani;AJNR,2002

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3