Harmonization of tumor mutation burden testing with comprehensive genomic profiling assays: an IQN Path initiative

Author:

Esposito Abate Riziero,Pasquale Raffaella,Sacco Alessandra,Simeon Vittorio,Maiello Monica Rosaria,Frezzetti Daniela,Chiodini Paolo,Normanno NicolaORCID

Abstract

BackgroundAlthough conflicting results emerged from different studies, the tumor mutational burden (TMB) appears as one of most reliable biomarkers of sensitivity to immune checkpoint inhibitors. Several laboratories are reporting TMB values when performing comprehensive genomic profiling (CGP) without providing a clinical interpretation, due to the lack of validated cut-off values. The International Quality Network for Pathology launched an initiative to harmonize TMB testing with CGP assay and favor the clinical implementation of this biomarker.MethodsTMB evaluation was performed with three commercially available CGP panels, TruSight Oncology 500 (TSO500), Oncomine Comprehensive Plus Assay (OCA) and QIAseq Multimodal Panel (QIA), versus the reference assay FoundationOne CDx (F1CDx). Archived clinical samples derived from 60 patients with non-small cell lung cancer were used for TMB assessment. Adjusted cut-off values for each panel were calculated.ResultsTesting was successful for 91.7%, 100%, 96.7% and 100% of cases using F1CDx, TSO500, OCA and QIA, respectively. The matrix comparison analysis, between the F1CDx and CGP assays, showed a linear correlation for all three panels, with a higher correlation between F1CDx and TSO500 (rho=0.88) than in the other two comparisons (rho=0.77 for QIA; 0.72 for OCA). The TSO500 showed the best area under the curve (AUC, value 0.96), with a statistically significant difference when compared with the AUC of OCA (0.83, p value=0.01) and QIA (0.88, p value=0.028). The Youden Index calculation allowed us to extrapolate TMB cut-offs of the different panels corresponding to the 10 mutations/megabase (muts/Mb) cut-off of F1CDx: 10.19, 10.4 and 12.37 muts/Mb for TSO500, OCA and QIA, respectively. Using these values, we calculated the relative accuracy measures for the three panels. TSO500 showed 86% specificity and 96% sensitivity, while OCA and QIA had lower yet similar values of specificity and sensitivity (73% and 88%, respectively).ConclusionThis study estimated TMB cut-off values for commercially available CGP panels. The results showed a good performance of all panels on clinical samples and the calculated cut-offs support better accuracy measures for TSO500. The validated cut-off values can drive clinical interpretation of TMB testing in clinical research and clinical practice.

Funder

Bristol Myers Squibb

QIAGEN

Illumina

Ministero della Salute

Thermo Fisher Scientific

AstraZeneca

Genentech

Merck KGaA

Roche

Publisher

BMJ

Subject

Cancer Research,Pharmacology,Oncology,Molecular Medicine,Immunology,Immunology and Allergy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3