End-tidal carbon dioxide output in manual cardiopulmonary resuscitation versus active compression-decompression device during prehospital quality controlled resuscitation: a case series study

Author:

Setälä Piritta AnniinaORCID,Virkkunen Ilkka Tapani,Kämäräinen Antti JaakkoORCID,Huhtala Heini Sisko Annamari,Virta Janne Severi,Yli-Hankala Arvi Mikael,Hoppu Sanna Elisa

Abstract

BackgroundActive compression–decompression (ACD) devices have enhanced end-tidal carbon dioxide (ETCO2) output in experimental cardiopulmonary resuscitation (CPR) studies. However, the results in out-of-hospital cardiac arrest (OHCA) patients have shown inconsistent outcomes, and earlier studies lacked quality control of CPR attempts. We compared manual CPR with ACD-CPR by measuring ETCO2 output using an audiovisual feedback defibrillator to ensure continuous high quality resuscitation attempts.Methods10 witnessed OHCAs were resuscitated, rotating a 2 min cycle with manual CPR and a 2 min cycle of ACD-CPR. Patients were intubated and the ventilation rate was held constant during CPR. CPR quality parameters and ETCO2 values were collected continuously with the defibrillator. Differences in ETCO2 output between manual CPR and ACD-CPR were analysed using a linear mixed model where ETCO2 output produced by a summary of the 2 min cycles was included as the dependent variable, the patient as a random factor and method as a fixed effect. These comparisons were made within each OHCA case to minimise confounding factors between the cases.ResultsMean length of the CPR episodes was 37 (SD 8) min. Mean compression depth was 76 (SD 1.3) mm versus 71 (SD1.0) mm, and mean compression rate was 100 per min (SD 6.7) versus 105 per min (SD 4.9) between ACD-CPR and manual CPR, respectively. For ETCO2 output, the interaction between the method and the patient was significant (P<0.001). ETCO2 output was higher with manual CPR in 6 of the 10 cases.ConclusionsThis study suggests that quality controlled ACD-CPR is not superior to quality controlled manual CPR when ETCO2 is used as a quantitative measure of CPR effectiveness.Trial registration numberNCT00951704; Results.

Funder

FinnHEMS Ltd

the Competitive Research Funding of Tampere University Hospital

Publisher

BMJ

Subject

Critical Care and Intensive Care Medicine,General Medicine,Emergency Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3