Five-day evaluation of the acceptability and comfort of wearable technology at four anatomical locations during military training

Author:

Taylor NatalieORCID,Carroll A,Gifford R MORCID

Abstract

IntroductionWearable sensor technologies enable Defence to optimise human performance, remotely identify physiological abnormalities and enhance medical support. Maximising the acceptability of devices will ensure they are worn alongside other equipment. This study assessed the acceptability and comfort of four devices at different anatomical locations during military training.MethodA cross-sectional pilot study during a live firing infantry exercise or adventurous training assessed four anatomical locations concurrently over 5 days: finger, wrist, upper arm and chest. Participants rated comfort, acceptability and preference using a standardised questionnaire after 12 hours and 5 days of wear.ResultsTwenty-one regular British Army personnel soldiers participated, aged 24.4 (4.3) years. The upper arm location received the highest rating by participants for comfort, followed in order by wrist, finger and chest (p=0.002, Χ2=40.0). The finger was most commonly identified as uncomfortable during specific activities (76%), followed by chest (48%), wrist (23%) and upper arm devices (14%). There was no significant difference in participant confidence in the devices to collect data or allow movement, but there was a trend towards greater confidence in upper arm and wrist locations to stay in position than the others (p=0.059, Χ2=28.0). After 5 days of wear, 43% of participants said they preferred the upper arm for comfort, followed by wrist (36%), finger (24%) and chest (10%). 73% and 71% would wear the wrist and upper arm devices on deployed operations, compared with 29% and 24% for chest and finger devices, respectively.ConclusionThe upper arm location offered greater acceptability and comfort than finger, wrist or chest locations. It is essential to consider such findings from occupationally relevant settings when selecting wearable technology. A larger service evaluation in diverse settings is recommended to guide the choice of the most acceptable wearable devices across different equipment, roles and environments.

Publisher

BMJ

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3