Validation of revised patient measures of safety: PMOS-30 and PMOS-10

Author:

Louch GemmaORCID,Reynolds Caroline,Moore Sally,Marsh Claire,Heyhoe Jane,Albutt Abigail,Lawton RebeccaORCID

Abstract

ObjectivesThere is growing evidence that patients can provide feedback on the safety of their care. The 44-item Patient Measure of Safety (PMOS) was developed for this purpose. While valid and reliable, the length of this questionnaire makes it potentially challenging for routine use. Our study aimed to produce revised, shortened versions of PMOS (PMOS-30 and PMOS-10), which retained the psychometric properties of the longer version.ParticipantsTo produce a shortened diagnostic measure, we analysed data from 2002 patients who completed PMOS-44, and examined the reliability of the revised measure (PMOS-30) in a sample of 751 patients. To produce a brief standalone measure, we again analysed data from 2002 patients who completed PMOS-44, and tested the reliability and validity of the brief standalone measure (PMOS-10) in a sample of 165 patients.MethodsThe process of shortening the questionnaire involved a combination of secondary data analysis (eg, Standard Deviation and inter-item correlations) and a consensus group exercise to produce PMOS-30 and examine face validity. Analysis of PMOS-30 data examined reliability (eg, Cronbach’s alpha). Further secondary data analysis (ie, corrected item-total correlations) produced PMOS-10, and primary data collection assessed its reliability and validity (eg, Cronbach’s alpha, analysis of variance).ResultsFourteen items were removed to produce PMOS-30 and the percentage of negatively worded items was reduced from 57% to 33%. PMOS-30 demonstrated good internal reliability (α=0.89). The 10 items with the highest corrected item-total correlations across both PMOS-44 and PMOS-30 composed PMOS-10. PMOS-10 had good internal reliability (α=0.79), demonstrated convergent validity; however, discriminant validity was not established.ConclusionsTwo revised, shortened versions of the original PMOS-44 (PMOS-30 and PMOS-10) were produced to capture patient feedback about safety in hospital. The measures demonstrated good reliability and validity, and preserved the psychometric properties of the original measure.

Funder

National Institute for Health Research

Health Foundation

Publisher

BMJ

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3