Atrial fibrillation detected at screening is not a benign condition: outcomes in screen-detected versus clinically detected atrial fibrillation. Results from the Prevention of Renal and Vascular End-stage Disease (PREVEND) study

Author:

Zwartkruis Victor WORCID,Geelhoed Bastiaan,Suthahar NavinORCID,Bakker Stephan J LORCID,Gansevoort Ron T,van Gelder Isabelle C,de Boer Rudolf AORCID,Rienstra MichielORCID

Abstract

AimsIt is unknown whether screen-detected atrial fibrillation (AF) carries cardiovascular risks similar to clinically detected AF. We aimed to compare clinical outcomes between individuals with screen-detected and clinically detected incident AF.MethodsWe studied 8265 participants (age 49 ± 13 years, 50% women) without prevalent AF from the community-based Prevention of Renal and Vascular End-stage Disease (PREVEND) study. By design of the PREVEND study, 70% of participants had a urinary albumin concentration >10 mg/L. Participants underwent 12-lead ECG screening at baseline and every 3 years. AF was considered screen-detected when first diagnosed during a study visit and clinically detected when first diagnosed during a hospital visit. We analysed data from the baseline visit (1997–1998) up to the third follow-up visit (2008). We used Cox regression with screen-detected and clinically detected AF as time-varying covariates to study the association of screen-detected and clinically detected AF with all-cause mortality, incident heart failure (HF) and vascular events.ResultsDuring a follow-up of 9.8 ± 2.3 years, 265 participants (3.2%) developed incident AF, of whom 60 (23%) had screen-detected AF. The majority of baseline characteristics were comparable between individuals with screen-detected and clinically detected AF. Unadjusted, both screen-detected and clinically detected AF were strongly associated with mortality, incident HF, and vascular events. After multivariable adjustment, screen-detected and clinically detected AF remained significantly associated with mortality (HR 2.21 (95% CI 1.09 to 4.47) vs 2.95 (2.18 to 4.00), p for difference=0.447) and incident HF (4.90 (2.28 to 10.57) vs 3.98 (2.49 to 6.34), p for difference=0.635). After adjustment, screen-detected AF was not significantly associated with vascular events, whereas clinically detected AF was (1.12 (0.46 to 2.71) vs 1.92 (1.21 to 3.06), p for difference=0.283).ConclusionScreen-detected incident AF was associated with an increased risk of adverse outcomes, especially all-cause mortality and incident HF. The risk of outcomes was not significantly different between screen-detected AF and clinically detected AF.

Funder

Hartstichting

Nierstichting

Publisher

BMJ

Subject

Cardiology and Cardiovascular Medicine

Reference36 articles.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3