Investigation of the performance of ground-coupled heat exchanger technology for tempering air

Author:

GOOROOCHURN Mahendra1,MUNGUR Maheshsingh1,SHAMACHURN Heman1,SURNAM Yashwansingh1,MANDARKHAN Fardeen1,BHOODOO Devin1

Affiliation:

1. University of Mauritius

Abstract

A horizontal ground heat exchanger has been applied as a simpler sustainability measure in buildings compared to its vertical counterpart, making it more suitable for residential application. A lack of contextual scientific findings within the specific construction culture has precluded its widespread application in the developing world. In this study, an experimental and simulation investigation was carried out on the thermal performance of an air-based horizontal ground-coupled heat exchanger buried 3 m below the ground. The study was performed in the tropical climate of Mauritius with a focus on space cooling. The ground temperature and air temperature inside the pipeline at several locations of the installation was measured. A CFD simulation model was developed and calibrated against the experimental data, which allowed further analyses on the influence of system parameters on performance. The study allowed to confirm the performance of the technology for application as a sustainability measure in the local construction industry and to identify practical challenge that need to be addressed. A drop in temperature of up to 5C was achieved at 2.3 m/s and 8C at 4 m/s. The latter result holds promise to achieve thermal comfort by achieving indoor air temperature of 27 C or lower when ambient air is at 33-34C during typical summer periods.

Publisher

Journal of Energy Systems

Subject

Management, Monitoring, Policy and Law,Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment

Reference17 articles.

1. [1] Lund, J., Freeston, D. World-wide direct uses of geothermal energy 2000. Geothermics 2001; 30 (1): 29-68.

2. [2] Lund, J. GEOTHERMAL HEAT PUMPS - TRENDS AND COMPARISONS - Geo-Heat Center.

3. [3] Im, P, Hughes, P, Liu, X, Ridge, O. Demonstration and performance monitoring of foundation heat exchangers (FHX) in ultra-high energy efficient research Homes Field test of the foundation heat exchanger concept. In: 17th ACEEE Summer Study on Energy Efficiency in Buildings; 12-17 August 2012: Pacific Grove, CA, pp. 114-126

4. [4] Xu, H, Spitler, JD. The relative importance of moisture transfer, soil freezing and snow cover on ground temperature predictions. Renewable Energy 2014; 72: 1-11.

5. [5] Busby, J. Determination of thermal properties for horizontal ground collector loops. In: Proceedings of World Geothermal Congress 2015; 19-25 April 2015: Melbourne, Australia, pp. 19-25.