Reverse shoulder arthroplasty with a 155° neck-shaft angle inlay implant design without reattachment of the subscapularis tendon results in satisfactory functional internal rotation and no instability: a cohort study

Author:

Macken Arno A.ORCID,van der Poel Wouter J.,Buijze Geert A.,Beckers Joris J.,Eygendaal Denise,Lafosse Laurent,Lafosse Thibault

Abstract

Abstract Background The aim of this study was to use the Activities of Daily Living which require Internal Rotation (ADLIR) questionnaire to assess the functional internal rotation in patients who had undergone reverse shoulder arthroplasty (RSA) without reattachment of the subscapularis (SSc) tendon at a minimum follow-up of 2 years. The secondary aim was to report the objective range of motion (ROM) and the rate of postoperative instability. Materials and methods All consecutive primary RSA procedures without reattachment of the SSc tendon that were performed using a Delta Xtend prosthesis (an inlay system with a 155° neck-shaft angle) between January 2015 and December 2020 were identified to ensure a minimum follow-up of 2 years. Patients were contacted and requested to fill in several questionnaires, including the ADLIR and Auto-Constant scores. Results In total, 210 patients met the inclusion criteria; among those patients, 187 could be contacted and 151 completed questionnaires (response rate: 81%). The SSc tendon was fully detached without repair in all cases, and a superolateral approach was used in 130 (86%) cases. The median follow-up was 4.5 years (range: 2.0–7.6). At final follow-up, the mean ADLIR score was 88/100 (interquartile range (IQR): 81–96). The median level reached in internal rotation was the 3rd lumbar vertebra (IQR: lumbosacral region—12th thoracic vertebra). Of the 210 eligible patients, one required a revision for a dislocation within the first month after primary surgery. With regards to regression analysis with ADLIR score as the outcome, none of the factors were associated with the ADLIR score, although age and smoking approached significance (0.0677 and 0.0594, respectively). None of the explanatory variables were associated with ROM in internal rotation (p > 0.05). Conclusions This study demonstrates that satisfactory ADLIR scores and internal rotation ROM were obtained at mid-term follow-up after RSA leaving the SSc detached. Leaving the SSc detached also did not lead to high instability rates; only one out of 210 prostheses was revised for dislocation within the first month after primary surgery. Level of evidence III.

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3