Ventilation dynamics using a portable device coupled to the six-minute walk test in people with long-COVID syndrome: a preliminary study

Author:

Oliveira Jéssica Gabriela MessiasORCID,Campos Renan PereiraORCID,Azevedo Beatriz Luiza Pinheiro AlvesORCID,de Alegria Samantha GomesORCID,Litrento Patrícia FrascariORCID,Mafort Thiago ThomazORCID,Lopes Agnaldo JoséORCID

Abstract

Abstract Objective To investigated the dynamic ventilatory responses and their influence on functional exercise capacity in patients with long-COVID-19 syndrome (LCS). Results Sixteen LCS patients were subjected to resting lung function (spirometry and respiratory oscillometry-RO) and cardiopulmonary performance to exercise (Spiropalm®-equipped six-minute walk test-6MWT and cardiopulmonary exercise test-CPX). At rest, spirometry showed a normal, restrictive and obstructive pattern in 87.5%, 6.25% and 6.25% of participants, respectively. At rest, RO showed increased resonance frequency, increased integrated low-frequency reactance and increased difference between resistance at 4–20 Hz (R4-R20) in 43.7%, 50%, and 31.2% of participants, respectively. The median of six-minute walking distance (DTC6) was 434 (386–478) m, which corresponds to a value of 83% (78–97%) of predicted. Dynamic hyperinflation (DH) and reduced breathing reserve (BR) were detected in 62.5% and 12.5% of participants, respectively. At CPX, the median peak oxygen uptake (VO2peak) was 19 (14–37) ml/kg/min. There was a significant correlation of 6MWD with both R4-R20 (rs=-0.499, P = 0.039) and VO2peak (rs=0.628, P = 0.009). Our results indicate that DH and low BR are contributors to poor exercise performance, which is associated with peripheral airway disease. These are promising results considering that they were achieved with simple, portable ventilatory and metabolic systems.

Funder

Conselho Nacional de Desenvolvimento Científico e Tecnólogico

Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Publisher

Springer Science and Business Media LLC

Subject

General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3