SYRMEP Tomo Project: a graphical user interface for customizing CT reconstruction workflows
-
Published:2017-01-19
Issue:1
Volume:3
Page:
-
ISSN:2198-0926
-
Container-title:Advanced Structural and Chemical Imaging
-
language:en
-
Short-container-title:Adv Struct Chem Imag
Author:
Brun FrancescoORCID, Massimi Lorenzo, Fratini Michela, Dreossi Diego, Billé Fulvio, Accardo Agostino, Pugliese Roberto, Cedola Alessia
Abstract
AbstractWhen considering the acquisition of experimental synchrotron radiation (SR) X-ray CT data, the reconstruction workflow cannot be limited to the essential computational steps of flat fielding and filtered back projection (FBP). More refined image processing is often required, usually to compensate artifacts and enhance the quality of the reconstructed images. In principle, it would be desirable to optimize the reconstruction workflow at the facility during the experiment (beamtime). However, several practical factors affect the image reconstruction part of the experiment and users are likely to conclude the beamtime with sub-optimal reconstructed images. Through an example of application, this article presents SYRMEP Tomo Project (STP), an open-source software tool conceived to let users design custom CT reconstruction workflows. STP has been designed for post-beamtime (off-line use) and for a new reconstruction of past archived data at user’s home institution where simple computing resources are available. Releases of the software can be downloaded at the Elettra Scientific Computing group GitHub repository https://github.com/ElettraSciComp/STP-Gui.
Publisher
Springer Science and Business Media LLC
Subject
Spectroscopy,Radiology, Nuclear Medicine and imaging,Chemical Engineering (miscellaneous)
Reference30 articles.
1. Bravin, A., Coan, P., Coan, P.: X-ray phase-contrast imaging: from pre-clinical applications towards clinics. Phys. Med. Biol. 58(1), 1–35 (2013) 2. Fratini, M., Bukreeva, I., Campi, G., Brun, F., Tromba, G., Modregger, P., Bucci, D., Battaglia, G., Spanó, R., Mastrogiacomo, M., Requardt, H., Giove, F., Bravin, A., Cedola, A.: Simultaneous submicrometric 3D imaging of the micro-vascular network and the neuronal system in a mouse spinal cord. Scientific Reports 5 (2014) 3. Mokso, R., Marone, F., Irvine, S., Nyvlt, M., Schwyn, D., Mader, K., Taylor, G.K., Krapp, H.G., Skeren, M., Stampanoni, M.: Advantages of phase retrieval for fast X-ray tomographic microscopy. J. Phys. D: Appl. Phys. 46(49) (2013) 4. Longo, R., Arfelli, F., Bellazzini, R., Bottigli, U., Brez, A., Brun, F., Brunetti, A., Delogu, P., Di Lillo, F., Dreossi, D., Fanti, V., Fedon, C., Golosio, B., Lanconelli, N., Mettivier, G., Minuti, M., Oliva, P., Pinchera, M., Rigon, L., Russo, P., Sarno, A., Spandre, G., Tromba, G., Zanconati, F.: Towards breast tomography with synchrotron radiation at Elettra: first images. Phys. Med. Biol. 61(4), 1634–1649 (2016) 5. Burvall, A., Lundström, U., Takman, P.A.C., Larsson, D.H., Hertz, H.M.: Phase retrieval in X-ray phase-contrast imaging suitable for tomography. Opt. Express 19(11), 10359–10376 (2011)
Cited by
124 articles.