Estimation of renal perfusion based on measurement of rubidium-82 clearance by PET/CT scanning in healthy subjects

Author:

Langaa Stine SundgaardORCID,Lauridsen Thomas Guldager,Mose Frank Holden,Fynbo Claire Anne,Theil Jørn,Bech Jesper Nørgaard

Abstract

Abstract Background Changes in renal blood flow (RBF) may play a pathophysiological role in hypertension and kidney disease. However, RBF determination in humans has proven difficult. We aimed to confirm the feasibility of RBF estimation based on positron emission tomography/computed tomography (PET/CT) and rubidium-82 (82Rb) using the abdominal aorta as input function in a 1-tissue compartment model. Methods Eighteen healthy subjects underwent two dynamic 82Rb PET/CT scans in two different fields of view (FOV). FOV-A included the left ventricular blood pool (LVBP), the abdominal aorta (AA) and the majority of the kidneys. FOV-B included AA and the kidneys in their entirety. In FOV-A, an input function was derived from LVBP and from AA, in FOV-B from AA. One-tissue compartmental modelling was performed using tissue time activity curves generated from volumes of interest (VOI) contouring the kidneys, where the renal clearance of 82Rb is represented by the K1 kinetic parameter. Total clearance for both kidneys was calculated by multiplying the K1 values with the volume of VOIs used for analysis. Intra-assay coefficients of variation and inter-observer variation were calculated. Results For both kidneys, K1 values derived from AA did not differ significantly from values obtained from LVBP, neither were significant differences seen between AA in FOV-A and AA in FOV-B, nor between the right and left kidneys. For both kidneys, the intra-assay coefficients of variation were low (~ 5%) for both input functions. The measured K1 of 2.80 ml/min/cm3 translates to a total clearance for both kidneys of 766 ml/min/1.73 m2. Conclusion Measurement of renal perfusion based on PET/CT and 82Rb using AA as input function in a 1-tissue compartment model is feasible in a single FOV. Based on previous studies showing 82Rb to be primarily present in plasma, the measured K1 clearance values are most likely representative of effective renal plasma flow (ERPF) rather than estimated RBF values, but as the accurate calculation of total clearance/flow is very much dependent on the analysed volume, a standardised definition for the employed renal volumes is needed to allow for proper comparison with standard ERPF and RBF reference methods.

Funder

Axel Muusfeldts Fond

The Research Foundation of the Central Denmark Region

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3