Author:
Vass Laurence D.,Lee Sarah,Wilson Frederick J.,Fisk Marie,Cheriyan Joseph,Wilkinson Ian
Abstract
Abstract
Introduction
Compartmental modelling is an established method of quantifying 18F-FDG uptake; however, only recently has it been applied to evaluate pulmonary inflammation. Implementation of compartmental models remains challenging in the lung, partly due to the low signal-to-noise ratio compared to other organs and the lack of standardisation. Good reproducibility is a key requirement of an imaging biomarker which has yet to be demonstrated in pulmonary compartmental models of 18F-FDG; in this paper, we address this unmet need.
Methods
Retrospective subject data were obtained from the EVOLVE observational study: Ten COPD patients (age =66±9; 8M/2F), 10 α1ATD patients (age =63±8; 7M/3F) and 10 healthy volunteers (age =68±8; 9M/1F) never smokers. PET and CT images were co-registered, and whole lung regions were extracted from CT using an automated algorithm; the descending aorta was defined using a manually drawn region. Subsequent stages of the compartmental analysis were performed by two independent operators using (i) a MIAKATTM based pipeline and (ii) an in-house developed pipeline. We evaluated the metabolic rate constant of 18F-FDG (Kim) and the fractional blood volume (Vb); Bland-Altman plots were used to compare the results. Further, we adjusted the in-house pipeline to identify the salient features in the analysis which may help improve the standardisation of this technique in the lung.
Results
The initial agreement on a subject level was poor: Bland-Altman coefficients of reproducibility for Kim and Vb were 0.0031 and 0.047 respectively. However, the effect size between the groups (i.e. COPD, α1ATD and healthy subjects) was similar using either pipeline. We identified the key drivers of this difference using an incremental approach: ROI methodology, modelling of the IDIF and time delay estimation. Adjustment of these factors led to improved Bland-Altman coefficients of reproducibility of 0.0015 and 0.027 for Kim and Vb respectively.
Conclusions
Despite similar methodology, differences in implementation can lead to disparate results in the outcome parameters. When reporting the outcomes of lung compartmental modelling, we recommend the inclusion of the details of ROI methodology, input function fitting and time delay estimation to improve reproducibility.
Publisher
Springer Science and Business Media LLC
Subject
Radiology Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation
Reference39 articles.
1. Chen D, Kinahan P. Multimodality molecular imaging of the lung. J Magn Reson Imaging. 2010; 32(6):1409–20. https://doi.org/10.1002/jmri.22385.Multimodality.
2. Chen DL, Cheriyan J, Chilvers ER, Choudhury G, Coello C, Connell M, Fisk M, Groves AM, Gunn RN, Holman BF, Hutton BF, Lee S, MacNee W, Mohan D, Parr D, Subramanian D, Tal-Singer R, Thielemans K, van Beek EJR, Vass L, Wellen JW, Wilkinson I, Wilson FJ. Quantification of lung PET images: challenges and opportunities. J Nuclear Med. 2017; 58(2):201–7. https://doi.org/10.2967/jnumed.116.184796.
3. Jones HA, Cadwallader KA, White JF, Uddin M, Peters AM, Chilvers ER. Dissociation between respiratory burst activity and deoxyglucose uptake in human neutrophil granulocytes : implications for interpretation of 18F-FDG PET images. J Nuclear Med. 2002; 43(5):652–7.
4. Holman BF, Cuplov V, Hutton BF, Groves AM, Thielemans K. The effect of respiratory induced density variations on non-TOF PET quantitation in the lung,. Phys Med Biol. 2016; 61(8):3148–63. https://doi.org/10.1088/0031-9155/61/8/3148.
5. Gunn RN, Gunn SR, Cunningham VJ. Positron emission tomography compartmental models. J Cereb Blood Flow Metab Off J Int Soc Cereb Blood Flow Metab. 2001; 21(6):635–52. https://doi.org/10.1097/00004647-200106000-00002.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献