Background
Graft malposition is a risk factor for failure of anterior cruciate ligament reconstruction. A 70° arthroscope improves visualisation of the medial wall of the lateral femoral condyle without switching portals. We investigated whether the use of this arthroscope affected the accuracy and precision of femoral tunnel placement.
Methods
Fifty consecutive adult patients were recruited. Following one withdrawal and two exclusions, 47 patients (30 in group 1 (70° arthroscope), 17 in group 2 (30° arthroscope)) underwent three-dimensional computed tomography imaging using a grid-based system to measure tunnel position.
Results
No difference was found in the accuracy or precision of tunnels (mean position: group 1 = 33.3 ± 6.0% deep–shallow, 27.2 ± 5.2% high–low; group 2 = 31.7 ± 6.9% deep–shallow, 29.0 ± 6.2% high–low; not significant). A post-hoc power analysis suggests a study of 106 patients would be required.
Conclusions
This pilot study suggests that tunnel position is not affected by the arthroscope used. An appropriately powered study could investigate this finding alongside other potential benefits of using a 70° arthroscope for this procedure.