Robotic- and orthosensor-assisted versus manual (ROAM) total knee replacement: a study protocol for a randomised controlled trial

Author:

Clement Nick D.ORCID,Bardgett Michelle,Galloway Steven,Baron Y. Jenny,Smith Karen,Weir David J.,Deehan David J.

Abstract

Abstract Background Robotic-arm-assisted knee arthroplasty allows for more accurate component positioning and alignment and is associated with better patient-reported outcomes compared to manually performed jig-based knee arthroplasty. However, what is not known is whether the addition of an intra-articular sensor (VerasenseTM) to aid intraoperative balancing of the total knee replacement (TKR) offers improved functional outcomes for the patient. The purpose of this research is to compare the outcomes of patients undergoing a conventional manual knee replacement to those undergoing TKR using robotic-assisted surgery and the VerasenseTM to optimise alignment and balance the knee joint, respectively, and assess the associated cost economics of such technology. Methods and analysis This randomised controlled trial will include 90 patients with end-stage osteoarthritis of the knee undergoing primary TKR. Patients meeting the inclusion/exclusion criteria that consent to be in the study will be randomised at a ratio of 1:1 to either manual TKR (standard of care) or robotic-arm-assisted TKR with VerasenseTM to aid balancing of the knee. The primary objective will be functional improvement at 6 months following surgery between the two groups. The secondary objectives are to compare changes in knee-specific function, joint awareness, patient expectation and fulfilment, satisfaction, pain, stiffness and functional ability, health-related quality of life, cost-effectiveness, and gait patterns between the two groups. Ethical approval was obtained by the Tyne & Wear South Research Ethics Committee, UK. The study is sponsored by the Newcastle Hospitals NHS Foundation Trust. Discussion This study will assess whether the improved accuracy of component positioning using the robotic-arm-assisted surgery and the VerasenseTM to aid balancing of the TKR offers improved outcome relative to standard manual jig-based systems that are currently the standard of care. This will be assessed primarily according to knee-specific function, but several other measures will also be assessed including whether these are cost-effective interventions. Trial registration International Standard Randomised Controlled Trial Number ISRCTN47889316 10.1186/ISRCTN47889316. Registered on 25 November 2019 Date and version for protocol ROAM Protocol V1.0 (13-12-2018)

Funder

Stryker

Publisher

Springer Science and Business Media LLC

Subject

Pharmacology (medical),Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3