Author:
Han Min,Xiao Heping,Yan Liping
Abstract
Abstract
Background
Tuberculous pleurisy (TBP) is the most common form of extrapulmonary tuberculosis (TB). However, rapid diagnostic methods with high accuracy for tuberculous pleurisy are urgently needed. In the present study, we evaluated the diagnostic accuracy of Xpert MTB/RIF, LAMP and SAT-TB assay with pleural fluids from culture-positive TBP patients.
Methods
We prospectively enrolled 300 patients with exudative pleural effusions used as the samples for Xpert MTB/RIF, LAMP and SAT-TB assay. Of these, 265 including 223 patients diagnosed with TBP and 42 non-TBP patients used as controls were analyzed.
Results
The sensitivities of Xpert MTB/RIF (27.4%), LAMP (26.5%) and SAT-TB assay (32.3%) were significantly higher than that of pleural effusion smear (14.3%, X2 = 20.65, P < 0.001), whereas they were much lower than expected for the analysis of pleural effusion samples. Both SAT-TB assay and Xpert MTB/RIF demonstrated high specificities (100%) and PPVs (100%), but the NPVs of all of the tests were < 22%. The area under ROC curve of pleural effusion smear, LAMP, Xpert MTB/RIF and SAT-TB assays was 0.524 (95% CI 0.431–0.617), 0.632 (95% CI 0.553–0.71), 0.637 (95% CI 0.56–0.714) and 0.673 (95% CI 0.6–0.745). SAT-TB assays had the highest AUC.
Conclusion
Nucleic acid amplification tests are not the first choice in the diagnosis of tuberculous pleurisy. In this type of test, SAT-TB is recommended because of its low cost, relatively more accurate compared with the other two tests. This prospective study was approved by The Ethics Committee of the Shanghai Pulmonary Hospital (approval number: K19–148).
Trial registration
ClinicalTrials.gov identifier: ChiCTR1900026234 (Retrospectively registered). The registration date is September 28, 2019.
Funder
China Tuberculosis Clinical Trial Consortium
Publisher
Springer Science and Business Media LLC
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献