Comparison of microscopic and xpert MTB diagnoses of presumptive mycobacteria tuberculosis infection: retrospective analysis of routine diagnosis at Cape Coast Teaching Hospital

Author:

Asare Kwame Kumi,Azumah Daniel Edem,Adu-Gyamfi Czarina Owusua,Opoku Yeboah Kwaku,Adela Edward Morkporkpor,Afful Philip,Abotsi Godwin Kwami,Abban Ernest Awuakye,Duntu Paul Ekow,Anyamful Akwasi,Moses Alberta Bedford,Botchway Emmanuel,Mwintige Philimon,Kyei Samuel,Amoah Linda Eva,Ekuman Emmanuel Owusu

Abstract

Abstract Introduction Tuberculosis is a global health problem that causes 1. 4 million deaths every year. It has been estimated that sputum smear-negative diagnosis but culture-positive pulmonary TB diagnosis contribute to 12.6% of pulmonary TB transmission. TB diagnosis by smear microscopy smear has a minimum detection limit (LOD) of 5,000 to 10,000 bacilli per milliliter (CFU/ml) of sputum result in missed cases and false positives. However, GeneXpert technology, with a LOD of 131–250 CFU/ml in sputum samples and its implementation is believe to facilitate early detection TB and drug-resistant TB case. Since 2013, Ghana health Service (GHS) introduce GeneXpert MTB/RIF diagnostic in all regional hospitals in Ghana, however no assessment of performance between microscopy and GeneXpert TB diagnosis cross the health facilities has been reported. The study compared the results of routine diagnoses of TB by microscopy and Xpert MTB from 2016 to 2020 at the Cape Coast Teaching Hospital (CCTH). Methods The study compared routine microscopic and GeneXpert TB diagnosis results at the Cape Coast Teaching Hospital (CCTH) from 2016 to 2020 retrospectively. Briefly, sputum specimens were collected into 20 mL sterile screw-capped containers for each case of suspected TB infection and processed within 24 h. The samples were decontaminated using the NALC-NaOH method with the final NaOH concentration of 1%. The supernatants were discarded after the centrifuge and the remaining pellets dissolved in 1–1.5 ml of phosphate buffer saline (PBS) and used for diagnosis. A fixed smears were Ziehl-Neelsen acid-fast stain and observed under microscope and the remainings were used for GeneXpert MTB/RIF diagnosis. The data were analyze using GraphPad Prism. Results 50.11% (48.48–51.38%) were females with an odd ratio (95% CI) of 1.004 (0.944–1.069) more likely to report to the TB clinic for suspected TB diagnosis. The smear-positive cases for the first sputum were 6.6% (5.98–7.25%), and the second sputum was 6.07% (5.45–6.73%). The Xpert MTB-RIF diagnosis detected 2.93% (10/341) (1.42–5.33%) in the first and 5.44% (16/294) (3.14–8.69%) in the second smear-negative TB samples. The prevalence of Xpert MTB-RIF across smear positive showed that males had 56.87% (178/313) and 56.15% (137/244) and females had 43.13% (135/313) and 43.85% (107/244) for the first and second sputum. Also, false negative smears were 0.18% (10/5607) for smear 1 and 0.31% (16/5126) for smear 2. Conclusion In conclusion, the study highlights the higher sensitivity of the GeneXpert assay compared to traditional smear microscopy for detecting MTB. The GeneXpert assay identified 10 and 16 positive MTB from smear 1 and smear 2 samples which were microscopic negative.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3