Abstract
Abstract
Background
China has not yet established a national surveillance network such as NHSN from America, so there is still no large-scale investigations on central line-associated bloodstream infection (CLABSI) incidence. Several retrospective studies in China reported that the incidence of CLABSI varied due to inconsistent diagnostic criteria. We performed a nationwide survey to investigate the utilization rate of central venous catheters (CVCs) and the incidence of CLABSI in ICUs of different areas of China.
Methods
This is a prospective multi-center study. Patients admitted to ICUs with the use of CVCs between January 1, 2014 and December 31, 2018 were enrolled in this study. Hospitals were given the definition of catheter-related bloodstream infection as: a laboratory-confirmed bloodstream infection where CVC was in place on the date of event or the day before. The characteristics of patients, information of catheterization, implementation rates of precautions, and CLABSIs were collected. The statistical analysis was performed by SPSS 25.0 software and website of Open Source Epidemiologic Statistics for Public Health.
Results
A total of 38,212 patients and 466,585 catheter days were involved in surveillance. The average CLABSI incidence in a thousand catheter days was 1.50, the lowest incidence unit was in pediatric ICU (0/1000 catheter days), and the lowest incidence area was in Northeast China (0.77/1000 catheter days), while the highest incidence unit was in cardiac ICU (2.48/1000 catheter days) and the highest incidence area was in Eastern China (1.62/1000 catheter days). The average utilization rate of CVC was 42.85%, the lowest utilization rate was in pediatric ICU (5.85%) and in Central China (38.05%), while the highest utilization rate was in surgical ICU (64.92%) and in Western China (51.57%). Among the 702 CLABSI cases reported, a total of 735 strains of pathogens were cultured. Staphylococcus spp. was the most common organism isolated (27.07%), followed by Enterobacteriaceae (22.31%). The implementation rates of all precautions showed an upward trend during the study period (P ≤ 0.001).
Conclusion
The average incidence of CLABSI in ICUs in China is 1.5/1000 catheter days, similar to the rates reported in developed countries but lower than previous reports in China. CLABSI incidence showed regional differences in China. It is necessary to implement targeted surveillance of CLABSI cases by using standardized CLABSI surveillance definitions and methodologies.
Funder
Chinese Hospital Association
Publisher
Springer Science and Business Media LLC
Reference25 articles.
1. Leistner R, Hirsemann E, Bloch A, et al. Costs and prolonged length of stay of central venous catheter-associated bloodstream infections (CVC BSI): a matched prospective cohort study. Infection. 2014;42(1):31–6.
2. Mimoz O, Lucet JC, Kerforne T, et al. Skin antisepsis with chlorhexidine–alcohol versus povidone iodine–alcohol, with and without skin scrubbing, for prevention of intravascular-catheter-related infection (CLEAN): an open-label, multicentre, randomised, controlled, two-by-two factorial trial. Lancet. 2015;386(10008):2069–77.
3. Fu PR, Sun YB, Wang HF, et al. Central line-associated bloodstream infections in patients receiving parenteral nutrition: a prospective study. Chin Gen Pract. 2013;2:181–3.
4. Wang QH, Dong L, Jin K, et al. Analysis on the risk factors of central line-associated bloodstream infection. Chin J Clin Healthc. 2015;18(6):572–5.
5. Peng SL, Lu Y. Clinical epidemiology of central venous catheter-related bloodstream infections in an intensive care unit in China. J Crit Care. 2013;28(3):277–83.
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献