Validation of an ambulatory cough detection and counting application using voluntary cough under different conditions

Author:

Vizel Eldad,Yigla Mordechai,Goryachev Yulia,Dekel Eyal,Felis Vered,Levi Hanna,Kroin Isaac,Godfrey Simon,Gavriely Noam

Abstract

Abstract Background While cough is an important defence mechanism of the respiratory system, its chronic presence is bothersome and may indicate the presence of a serious disease. We hereby describe the validation process of a novel cough detection and counting technology (PulmoTrack-CC™, KarmelSonix, Haifa, Israel). Methods Tracheal and chest wall sounds, ambient sounds and chest motion were digitally recorded, using the PulmoTrack® hardware, from healthy volunteers coughing voluntarily while (a) laying supine, (b) sitting, (c) sitting with strong ambient noise, (d) walking, and (e) climbing stairs, a total of 25 minutes per subject. The cough monitoring algorithm was applied to the recorded data to detect and count coughs. The detection algorithm first searches for cough 'candidates' by identifying loud sounds with a cough pattern, followed by a secondary verification process based on detection of specific characteristics of cough. The recorded data were independently and blindly evaluated by trained experts who listened to the sounds and visually reviewed them on a sonogram display. The validation process was based on two methods: (i) Referring to an expert consensus as gold standard, and comparing each cough detected by the algorithm to the expert marking, we marked True and False, positive and negative detections.These values were used to evaluate the specificity and sensitivity of the cough monitoring system. (ii) Counting the number of coughs in longer segments (t = 60 sec, n = 300) and plotting the cough count vs. the corresponding experts' count whereby the linear regression equation, the regression coefficient (R 2) and the joint-distribution density Bland-Altman plots could be determined. Results Data were recorded from 12 volunteers undergoing the complete protocol. The overall Specificity for cough events was 94% and the Sensitivity was 96%, with similar values found for all conditions, except for the stair climbing stage where the Specificity was 87% with Sensitivity of 97%. The regression equation between the PulmoTrack-CC™ cough event counts and the Experts' determination was with R 2 of 0.94. Discussion This validation scheme provides an objective and quantitative assessment method of a cough counting algorithm in a range of realistic situations that simulate ambulatory monitoring of cough. The ability to detect voluntary coughs under acoustically challenging ambient conditions may represent a useful step towards a clinically applicable automatic cough detector.

Publisher

Springer Science and Business Media LLC

Subject

Pulmonary and Respiratory Medicine,Otorhinolaryngology

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Cough Detection Using Acceleration Signals and Deep Learning Techniques;Electronics;2024-06-20

2. SymRecorder: Detecting Respiratory Symptoms in Multiple Indoor Environments Using Earphone-Microphones;Communications in Computer and Information Science;2024

3. Technology Approaches for Cruise Ship Disease Propagation Monitoring;The Blue Book;2023-11-17

4. Tuberculosis detection based on cough sounds: a multi-model voting mechanism;2023 16th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI);2023-10-28

5. Nighttime Continuous Contactless Smartphone-Based Cough Monitoring for the Ward: Validation Study;JMIR Formative Research;2023-02-20

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3