Association between oxygen saturation level during bronchoscopy and post-bronchoscopy adverse events: a retrospective cohort study

Author:

Kim So Yeon,Lee Hyo Jin,Lee Jung Kyu,Park Tae Yeon,Heo Eun Young,Kim Deog Kyeom,Chung Hee Soon,Lee Hyun Woo

Abstract

Abstract Background Flexible bronchoscopy is widely used to diagnose and treat various respiratory diseases. However, caution is warranted for post-bronchoscopy adverse events. Although desaturation frequently occurs during bronchoscopy, its clinical impact and the optimal oxygen saturation level during the procedure remain unclear. This study aimed to investigate whether the percutaneous oxygen saturation (SpO2) level during bronchoscopy is associated with the development of post-bronchoscopy respiratory adverse events. Methods In this single-center retrospective cohort study conducted from March 2020 to February 2021, 569 patients were classified into high or low oxygen saturation groups based on the SpO2 level during bronchoscopy. The primary outcome was post-bronchoscopy respiratory adverse events, and secondary outcomes were other post-bronchoscopy adverse events and clinical outcomes. Results Among 569 patients, 458 and 111 patients were classified into the high oxygen saturation (SpO2 > 96%) and low oxygen saturation (SpO2 ≤ 94%) groups, respectively. After propensity score matching, the low oxygen saturation group had more post-bronchoscopy respiratory and febrile adverse events than the high oxygen saturation group. In the multivariable regression analysis, low SpO2 level during bronchoscopy was an independent risk factor for post-bronchoscopy respiratory adverse events (odds ratio = 3.16 [95% confidence interval 1.37–7.30]). In the low oxygen saturation group, the high-risk subgroups for post-bronchoscopy respiratory adverse events were the elderly, women, current smokers, and patients with chronic obstructive pulmonary disease or acute decompensated heart failure before bronchoscopy. There was no significant difference in the length of hospital stay, intensive care unit admission, or mortality between the high and low oxygen saturation groups. Conclusions Close monitoring is recommended for patients with SpO2 ≤ 94% during bronchoscopy due to the increased risk of respiratory adverse events after the procedure.

Funder

Seoul Metropolitan Government Seoul National University Boramae Medical Center,South Korea

Publisher

Springer Science and Business Media LLC

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3