Abstract
Abstract
Background
One of the challenges encountered by clinicians new to implant dentistry is the determination and controlling of implant location. This study compared the accuracy of fully guided (FG) and pilot-guided (PG) static computer-assisted implant placement (sCAIP) protocols against the conventional freehand (FH) protocol for placing single anterior and posterior implants by recently introduced clinicians to implant dentistry.
Material and methods
Ten clinicians new to implant dentistry inserted one anterior (central incisor) and one posterior (first molar) implants per protocol in training maxillary models. The FG protocol involved drilling and implant placement through the guide, while the PG protocol controlled the pilot drilling only. The FH implant placement was completed without the aid of any guide. A total of 30 models were used, and 60 implants were inserted. The implant vertical, horizontal neck, horizontal apex, and angle deviations from planned positions were calculated.
Results
The FG protocol provided the most accurate implant placement in relation to horizontal neck (0.47 mm–0.52 mm), horizontal apex (0.71 mm–0.74 mm), and angle deviations (2.42o–2.61o). The vertical deviation was not significantly different among the different protocols. The PG protocol was generally similar to the FH protocol with a horizontal neck deviation of 1.01 mm–1.14 mm, horizontal apex deviation of 1.02 mm–1.35 mm, and angle deviation of 4.65o–7.79o. The FG protocol showed similarity in the accuracy of the anterior and posterior implants. There was a tendency for inferior accuracy for posterior implants compared with anterior implants for the PG and FH protocols.
Conclusions
In the hands of recently introduced clinicians to implant dentistry, it appears that the accuracy of the FG protocol was superior to the other protocols and was not influenced by the position of the implants. The PG and FH protocols showed inferior accuracy for posterior implants compared with anterior implants.
Publisher
Springer Science and Business Media LLC
Reference29 articles.
1. Belser UC, Mericske-Stern R, Bernard JP, Taylor TD. Prosthetic management of the partially dentate patient with fixed implant restorations. Clin Oral Implants Res. 2000;11:126–45.
2. Buser D, Martin W, Belser UC. Optimizing esthetics for implant restorations in the anterior maxilla: anatomic and surgical considerations. Int J Oral Maxillofac Implants. 2004;19:43–61.
3. Ramaglia L, Toti P, Sbordone C, Guidetti F, Martuscelli R, Sbordone L. Implant angulation: 2-year retrospective analysis on the influence of dental implant angle insertion on marginal bone resorption in maxillary and mandibular osseous onlay grafts. Clin Oral Investig. 2015;19:69–779.
4. Hinckfuss S, Conrad HJ, Lin L, Lunos S, Seong WJ. Effect of surgical guide design and surgeon's experience on the accuracy of implant placement. J Oral Implantol. 2012;38:311–23.
5. Noharet R, Pettersson A, Bourgeois D. Accuracy of implant placement in the posterior maxilla as related to 2 types of surgical guides: a pilot study in the human cadaver. J Prosthet Dent. 2014;112:526–32.