Proportion of serum thyroid hormone concentrations within the reference ranges in athyreotic patients on levothyroxine monotherapy: a retrospective study

Author:

Ito MitsuruORCID,Takahashi Sawako,Okazaki-Hada Mikiko,Minakata Mizuho,Kohsaka Kazuyoshi,Nakamura Tomohiko,Kasahara Toshihiko,Kudo Takumi,Nishihara Eijun,Fukata Shuji,Nishikawa Mitsushige,Akamiuzu Takashi,Miyauchi Akira

Abstract

Abstract Background In patients receiving thyroid-stimulating hormone (TSH) suppressive therapy with levothyroxine (LT4) after total thyroidectomy for thyroid cancer, thyroid function tests should be performed to adjust the LT4 dose. Specifically, serum TSH concentrations are commonly measured because TSH suppression is necessary according to thyroid cancer risk. The aim of the present study was to elucidate whether free thyroxine (FT4) or free triiodothyronine (FT3) indicates better for adjusting the dose in athyreotic patients on LT4 monotherapy after total thyroidectomy. Methods We retrospectively studied the compatibility of free thyroid hormone (FT4 and FT3) concentrations with reference ranges in athyreotic patients on LT4 monotherapy after total thyroidectomy. Results We identified 2210 consecutive patients from their medical records. Of these patients, 250 had both FT4 and FT3 concentrations in addition to TSH. Two hundred seven had serum TSH concentrations below the reference range (0.5–5.0 μIU/mL), while 43 had them within the reference range. In the 207 patients with TSH concentrations below the reference range, 61 patients (29.5%) had FT4 concentrations within the reference range (0.9–1.7 ng/dL) and 146 patients (70.5%) had FT4 concentrations above the reference range. In contrast, 10 patients (4.8%) had FT3 concentrations below the reference range (2.3–4.0 pg/mL) and 8 (3.9%) had FT3 concentrations above the reference range; 189 patients (91.3%) had concentrations within the reference range. Of the 43 patients with TSH concentrations within the reference range, 25 (58.1%) had FT4 concentrations within the reference range and 18 (41.9%) had FT4 concentrations above the reference range. While, 11 patients (25.6%) had FT3 concentrations below the reference range and one (2.3%) had FT3 concentrations above the reference range; hence, 31 patients (72.1%) had FT3 concentrations within the reference range. Conclusion This study showed that measuring FT3 concentrations rather than FT4 concentrations as the subsequent parameter of thyroid function might be more useful for disease management in terms of the proportion of serum thyroid hormone concentrations within the reference ranges. Furthermore, FT3 measurement could be useful in providing more detailed treatments, including avoiding more aggressive TSH suppressive therapy and identifying the presence of low T3 syndrome in the background.

Publisher

Springer Science and Business Media LLC

Subject

Endocrine and Autonomic Systems,Endocrinology,Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3