An electrographic AV optimization for the maximum integrative atrioventricular and ventricular resynchronization in CRT

Author:

Li Jie,Wang Yuegang,Mai Jingting,Chen Shilan,Liu Menghui,Su Chen,Chen Xumiao,Huang Huiling,Ma Yuedong,Feng Chong,Jiang Jingzhou,Liu Jun,He Jiangui,Tang Anli,Dong Yugang,Huang Xiaobo,Chen Yangxin,Wang LichunORCID

Abstract

Abstract Background Atrioventricular (AV) delay could affect AV and ventricular synchrony in cardiac resynchronization therapy (CRT). Strategies to optimize AV delay according to optimal AV synchrony (AVopt-AV) or ventricular synchrony (AVopt-V) would potentially be discordant. This study aimed to explore a new AV delay optimization algorithm guided by electrograms to obtain the maximum integrative effects of AV and ventricular resynchronization (opt-AV). Methods Forty-nine patients with CRT were enrolled. AVopt-AV was measured through the Ritter method. AVopt-V was obtained by yielding the narrowest QRS. The opt-AV was considered to be AVopt-AV or AVopt-V when their difference was < 20 ms, and to be the AV delay with the maximal aortic velocity–time integral between AVopt-AV and AVopt-V when their difference was > 20 ms. Results The results showed that sensing/pacing AVopt-AV (SAVopt-AV/PAVopt-AV) were correlated with atrial activation time (Pend-As/Pend-Ap) (P < 0.05). Sensing/pacing AVopt-V (SAVopt-V/PAVopt-V) was correlated with the intrinsic AV conduction time (As-Vs/Ap-Vs) (P < 0.01). The percentages of patients with more than 20 ms differences between SAVopt-AV/PAVopt-AV and SAVopt-V/PAVopt-V were 62.9% and 57.1%, respectively. Among them, opt-AV was linearly correlated with SAVopt-AV/PAVopt-AV and SAVopt-V/PAVopt-V. The sensing opt-AV (opt-SAV) = 0.1 × SAVopt-AV + 0.4 × SAVopt-V + 70 ms (R2 = 0.665, P < 0.01) and the pacing opt-AV (opt-PAV) = 0.25 × PAVopt-AV + 0.5 × PAVopt-V + 30 ms (R2 = 0.560, P < 0.01). Conclusion The SAVopt-AV/PAVopt-AV and SAVopt-V/PAVopt-V were correlated with the atrial activation time and the intrinsic AV conduction interval respectively. Almost half of the patients had a > 20 ms difference between SAVopt-AV/PAVopt-AV and SAVopt-V/PAVopt-V. The opt-AV could be estimated based on electrogram parameters.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Heart failure in China: epidemiology and current management;Journal of Geriatric Cardiology;2024-06

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3