Efficacy and safety of self-made covered coronary stent in the treatment of coronary artery perforation

Author:

An Wen,Ye Jian,Han Bingyu,Wang Xu,Han Chao,Gao Junqing,Liu Zongjun

Abstract

Abstract Objective To observe the efficacy and safety of self-made covered coronary stent in the treatment of coronary artery perforation. Methods Covered coronary stent was prepared by wrapping 3 M film on the surface of coronary stents. The beagle dogs were divided into control group and experimental group. A drug-eluting stent (DES) was implanted in the control group. The covered stent was applied to block the coronary branches of beagle dogs. The CaIMR value after stent placement was calculated by FlashAngio software. The effect of blocking the coronary branches on blood flow was observed by coronary angiography (CAG). The condition of the implanted stent was observed by optical coherence tomography (OCT), and the histopathologic examination of the coronary vessel implanted stent was performed by HE staining. Results The best number of layers was 2. Compared with the control group, the CaIMR of the experimental group increased (p < 0.05). A lot of in-stent thrombosis were found in the experimental group and obvious blood flow obstruction during follow-up. HE staining showed that stents implanted in the two groups adhered well to the wall of the blood vessel, but in-stent thrombosis and intimal hyperplasia were founded in the experimental group, while the in-stent restenosis was not founded. Conclusion The self-made coronary covered stent can effectively block the leakage caused by coronary perforation, but the stent endothelialization is poor, which easily causes stent thrombosis and restenosis, so it is not recommended as a routine remedy.

Funder

“Innovation Project” of Shanghai Putuo District Health System Science and Technology

The Shanghai Key Medical Specialties Construction Project

Clinical Advantage Discipline of Health System of Putuo District in Shanghai

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Electrospun bioresorbable polymer membranes for coronary artery stents;Frontiers in Bioengineering and Biotechnology;2024-08-21

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3