Author:
Peters Florian,Raith Stefan,Bock Anna,Kniha Kristian,Ooms Mark,Möhlhenrich Stephan Christian,Hölzle Frank,Modabber Ali
Abstract
Abstract
Background
Tumorous diseases of the jaw demand effective treatments, often involving continuity resection of the jaw. Reconstruction via microvascular bone flaps, like deep circumflex iliac artery flaps (DCIA), is standard. Computer aided planning (CAD) enhances accuracy in reconstruction using patient-specific CT images to create three-dimensional (3D) models. Data on the accuracy of CAD-planned DCIA flaps is scarce. Moreover, the data on accuracy should be combined with data on the exact positioning of the implants for well-fitting dental prosthetics. This study focuses on CAD-planned DCIA flaps accuracy and proper positioning for prosthetic rehabilitation.
Methods
Patients post-mandible resection with CAD-planned DCIA flap reconstruction were evaluated. Postoperative radiograph-derived 3D models were aligned with 3D models from the CAD plans for osteotomy position, angle, and flap volume comparison. To evaluate the DCIA flap’s suitability for prosthetic dental rehabilitation, a plane was created in the support zone and crestal in the middle of the DCIA flap. The lower jaw was rotated to close the mouth and the distance between the two planes was measured.
Results
20 patients (12 males, 8 females) were included. Mean defect size was 73.28 ± 4.87 mm; 11 L defects, 9 LC defects. Planned vs. actual DCIA transplant volume difference was 3.814 ± 3.856 cm³ (p = 0.2223). The deviation from the planned angle was significantly larger at the dorsal osteotomy than at the ventral (p = 0.035). Linear differences between the planned DCIA transplant and the actual DCIA transplant were 1.294 ± 1.197 mm for the ventral osteotomy and 2.680 ± 3.449 mm for the dorsal (p = 0.1078). The difference between the dental axis and the middle of the DCIA transplant ranged from 0.2 mm to 14.8 mm. The mean lateral difference was 2.695 ± 3.667 mm in the region of the first premolar.
Conclusion
The CAD-planned DCIA flap is a solution for reconstructing the mandible. CAD planning results in an accurate reconstruction enabling dental implant placement and dental prosthetics.
Funder
Universitätsklinikum RWTH Aachen