Three-dimensional evaluation of bracket placement accuracy and excess bonding adhesive depending on indirect bonding technique and bracket geometry: an in-vitro study

Author:

Möhlhenrich Stephan ChristianORCID,Alexandridis Constantin,Peters Florian,Kniha Kristian,Modabber Ali,Danesh Golamreza,Fritz Ulrike

Abstract

Abstract Background This study aimed at comparing bracket placement and excess bonding adhesive depending on different indirect bonding (IDB) techniques and bracket geometries. Methods Four hundred eighty brackets without hook (WOH) and 360 with hook (WH) were placed on 60 plaster models. Three IDB techniques were tested: polyvinyl-siloxane vacuum-form (PVS-VF), polyvinyl-siloxane putty (PVS-putty), and translucence double-polyvinyl-siloxane (double-PVS). PVS-VF and PVS-putty were combined with chemically, and double-PVS was combined with light cured bonding adhesive. Virtual images of models before and after bracket transfer were generated, and computerized images were compared. Linear, angular deviations, and excess bonding adhesive were measured. Results Linear differences between the three groups were obtained for PVS-VF (WH: 1.08, SD 0.50 mm; WOH: 0.86, SD 0.25 mm), PVS-putty (WH: 0.73, SD 0.51 mm; WOH: 0.58, SD 0.28 mm), and double-PVS (WH: 0.65, SD 0.45 mm; WOH: 0.59, SD 0.33 mm) (P < 0.001). Hooks affected bracket placement accuracy in PVS-VF (P < 0.001) and PVS-putty (P = 0.029). Angular differences were observed for brackets WOH between the PVS-VF (0.64, SD 0.48°) and double-PVS group (0.92, SD 0.76°) (P < 0.001) and within double-PVS group (WH: 0.66, SD 0.51° vs. WOH: 0.92, SD 0.76°, P < 0.001). Highest amount of excess adhesive was obtained for PVS-putty group (WH: 6.54, SD 5.31 mm 2). Conclusions The double-PVS group revealed promising results with respect to transfer accuracy, whereas the PVS-VF group provided least excess bonding adhesive. Basically, hooks lead to lower precision and higher excess bonding adhesive. PVS trays for IDB generate high bracket placement accuracy. PVS-putty is the easiest to handle with and also the cheapest, but leads to large excess bonding adhesive, especially in combination with hooked brackets or tubes.

Publisher

Springer Science and Business Media LLC

Subject

Neurology (clinical),General Dentistry,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3